Skip to content
Close up of catalytic converter surface

Catalysts

Efficient H₂O₂ reduction: The key to safe and cost-effective processes

Learn more

Shorter aeration. More stable processes. A safer working environment.

In aseptic manufacturing environments, hydrogen peroxide (H₂O₂) is an established standard for bio-decontamination. One of the challenges, however, begins afterward: breaking down H₂O₂ completely and in a controlled manner without slowing processes or creating risks for product and personnel.
Catalysts play a central role here – as an invisible yet critical component of efficient decontamination and aeration concepts.

Where the real challenge begins

Aeration, exposure limits, and cycle times

  • Long aeration times

    After decontamination, the H₂O₂ concentration must drop quickly to safe levels. The aeration phase is often the bottleneck of the entire cycle.

  • Balancing safety and efficiency

    High H₂O₂ concentrations and conventional airflow concepts with large air volumes ensure effective decontamination, but they also extend aeration, increase energy consumption, and delay the return to production.

  • Regulatory requirements

    Exposure limits (e.g., in the ppm range) must be met reliably and reproducibly.

  • Material and process compatibility

    Residual H₂O₂ can affect products, surfaces, and processes.

Air handling in an isolator
How catalysts break down H₂O₂

From chemical principle to process performance

Without catalysis, H₂O₂ decomposes too slowly. The breakdown then depends mainly on how much air is passed through the system – a time-consuming and energy-intensive approach.

Catalysts accelerate decomposition by lowering the required activation energy. In the process, H₂O₂ is selectively converted into water and oxygen:

2 H₂O₂ → 2 H₂O + O₂

The catalyst itself remains chemically unchanged. Industrial applications rely on heterogeneous catalysis: gaseous H₂O₂ reacts on the surface of a solid catalyst. How efficiently this happens therefore depends heavily on the surface area and material structure – and on how the air is directed past that surface.

This results in a central design principle:
Maximum surface area + controlled airflow = maximum efficiency

However, catalysts act only on the H₂O₂ in the air. H₂O₂ that has penetrated materials such as gloves, seals, or plastics during decontamination off-gasses only slowly. Even with high-performance catalysis, material selection therefore remains an important factor in aeration time.

H2O2 decomposition by nanox catalyst
What sets modern catalysts apart

Materials, stability, and integration

Current developments show a clear trend away from conventional materials toward nanostructured systems. Their key characteristics include:

  • Metal-based nanostructures for high reactivity
  • Porous coatings on ceramic substrates with a large specific surface area (BET value > 200 m²/g)
  • Moisture management to keep humidity from blocking the active surface
  • Low pressure drop for energy-efficient airflow

This enables faster H₂O₂ breakdown with lower air volumes and more compact systems. And this performance is maintained over the long term: in a stress test with 50 kg of H₂O₂ (49.5% w/w) at 600 m³/h, the decomposition rate decreased by only approx. 0.015%.

What determines effectiveness in operation, however, is not just the material but how it is integrated into the system – in particular, volumetric flow rate, contact time, pressure drop, and position in the airflow.

Catalytic converter in isolator
Where catalysts make the difference

Applications at a glance

  • Isolators for aseptic manufacturing

    Shorter aeration translates directly into more production time.

  • Fill-finish lines

    Every hour of downtime is especially costly here.

  • Sterility testing systems

    Residual H₂O₂ can inhibit microbial growth and thus skew test results.

  • Decontamination airlocks

    Short cycles are a prerequisite for efficient material flow.

  • ATMPs and clinical manufacturing

    Frequent product changeovers and sensitive products require fast, thorough aeration.

  • Highly potent compounds and modular facilities

    Closed, compact systems require little or no external exhaust infrastructure.

What this means for operations

Cycle time, safety, and efficiency

When properly designed, catalysts have a direct impact on process performance: cycle times decrease, exposure limits are met reproducibly, and facility concepts become simpler – in some cases eliminating the need for external exhaust systems altogether – while reduced air volumes and low pressure drop cut energy consumption.

As requirements for flexibility, throughput, energy efficiency, and containment continue to rise, catalysts are evolving from a supporting component into a key lever for safe and cost-effective decontamination processes. SKAN pursues this approach with its nanox technology, which is integrated directly into its systems.

Man builds catalytic converter in assemly hall

Understand your decontamination processes in detail.

Talk to our experts about your specific application.