An isolator costs more to purchase than a RABS – and significantly less to operate. The difference lies not in the machine but in the room around it.

RABS and isolators pursue the same goal: they separate people from the critical zone and keep the work area at Grade A. EU GMP Annex 1 recognizes both as barrier technology. The difference lies in how strictly the separation is enforced. This determines how high the classification of the surrounding environment must be.

Which concept fits your process depends on just a few characteristics. This article goes through them one by one.

How the systems differ

“Background environment” is the decisive row, affecting capital and operating costs more than any other.

Open RABS, passive Open RABS, active cRABS closed, active Isolator
Work area Grade A Grade A Grade A Grade A
Background environment Grade B Grade B Grade B Grade C (open) / D (closed)
Airflow Via the room ceiling Dedicated supply air, exhaust into the room Dedicated, separate from the room Dedicated, separate from the room
Differential pressure to the room no no possible always
Bio-decontamination Together with the room Together with the room Independent operation possible Independent, automated
Barrier during production Can be opened Can be opened Can be opened Remains closed
Highly potent APIs no no eingeschränkt yes

Where the cost differences arise

Most calculations compare the machine. The bigger differences, however, arise in the surrounding environment: Grade B for the RABS (images on the left and in the center) versus Grade C or D for the isolator (image on the right).

  • RABS cleanroom filling containment application.

    Airlocks and gowning

    A Grade B room is typically accessed via three airlocks each for personnel and materials. Full Grade A/B gowning is required every time the room is entered, often several times per shift. An isolator requires only one personnel airlock and two material airlocks, and gowning is simpler and faster.

  • Personnel and monitoring

    In Grade B, personnel must be qualified for gowning, monitoring also covers gowns, and the environment is monitored continuously. Personnel training and qualification are also more demanding. With an isolator, this Grade A/B logic no longer applies to the surrounding room.

  • Operator monitoring integra filling line via touchscreen in cleanroom isolator environment.

    HVAC and energy

    Grade B rooms require significantly higher air change rates – and therefore more energy. This additional cost is incurred on every operating day, over the entire service life of the facility.

What the difference means over the life cycle

Isolator compared with cRABS

  • Approx. −15% floor space

    The Grade A area is the same size. The RABS, however, requires three additional cleanroom grades and twice as many airlocks.

  • Approx. +30% capital investment

    For the isolator, the machine and initial qualification are more expensive. For the RABS, on the other hand, HVAC costs are more than 60% higher, plus aseptic transfer systems.

  • Approx. −38% operating costs per year

    Gowning costs about three quarters less per operator, and monitoring just under half. Only requalification is more demanding for the isolator.

  • Approx. 6 years to break even

    With a service life of 15 years or more, the isolator then operates at a cost advantage for more than half of its life. Not included in the calculation is the fact that, based on experience, positive monitoring samples in the cleanroom are 100 to 1,000 times more frequent.

Model calculation for an aseptic filling and closing line (cRABS in Grade B versus isolator in Grade D). Source: Bässler/Lehmann, in: Gail/Gommel (eds.), Reinraumtechnik, Springer 2018, ch. 7.8.2. 

What determines the choice?

  • In an isolator, interventions are carried out via gloves and transfer systems. The barrier remains closed, and people stay outside the Grade A zone. This is exactly what Annex 1 requires: critical interventions in Grade A are to be reduced.

    Some malfunctions cannot be resolved via gloves – for example, glass breakage or jammed containers. With a RABS, the doors can be opened in such cases. The affected units are rejected, the line is cleared, and the opened area is disinfected manually. Production resumes only after the required contact time. Wipe disinfection of this kind is labor-intensive and difficult to validate. In addition, every open intervention brings people – the greatest source of contamination – close to the Grade A zone.

    With an isolator, opening is followed by cleaning and a complete, automated H₂O₂ decontamination cycle. This cycle renders the surfaces in the work area free of viable microorganisms, as demonstrated with biological indicators. It takes time but results in a validated, reproducible state.

  • With frequent changeovers, changeover time is what counts. For an isolator, it depends primarily on the decontamination cycle. Cycle times have dropped significantly in recent years, and spray-based methods shorten them further compared with conventional vaporization methods. [Link: H₂O₂ decontamination] Changeover time can therefore be controlled through design. If it is factored in from the outset, it remains low.

  • The additional investment in an isolator pays for itself after around six years. With typical service lives of 15 years or more, the cost advantage then applies for most of the facility’s life. Only if production is expected to run for a significantly shorter period is a RABS the more economical choice. 

  • The isolator separates people from the Grade A zone more strictly than a RABS does. Every aseptically manufactured product benefits from this: the higher the cleanliness requirements, the stronger the case for an isolator. For some products, an isolator is the only option – for example, highly potent APIs, where the operator must be protected as well, or oxygen- and moisture-sensitive products that require a defined atmosphere.

  • An isolator can also pay off in an existing facility. An existing Grade B cleanroom can be downgraded to Grade C or D. After requalification, the ongoing additional costs of Grade B for gowning, monitoring, and HVAC no longer apply. With a RABS, they remain for the entire service life, even if the initial investment in an existing facility may be lower. For a new build, the surrounding environment can be designed for the isolator from the start.

What does Annex 1 require?

The revised EU GMP Annex 1 recommends barrier technologies to protect against contamination from personnel, materials, and the environment (2.1) and aims to reduce critical interventions in the Grade A zone (8.9). Anyone using neither a RABS nor an isolator must justify this (4.3).

Annex 1 leaves open which of the two systems is used. It requires a traceable justification of the choice in the Contamination Control Strategy. This includes how interventions are controlled with the chosen system. For a RABS, it must be demonstrated that no air enters the critical zone when doors are opened (4.20). Open interventions are therefore considered an exception in the event of malfunctions, not part of the routine process. For an isolator, this question does not arise: it remains closed during production.

Still undecided between an isolator and a RABS?

Talk to our experts about your process, your facility, and the planned service life of your system.