Safe change filter in an isolator

Filters in aseptic manufacturing

Why HEPA filters determine product quality

Learn more

In aseptic processes, controlled airflow is not a supporting element – it is a critical component of sterility assurance.

High-efficiency filters ensure that particles and microorganisms are reliably removed from the air before they reach the process area.
At the same time, requirements are becoming increasingly stringent: new therapies, more complex processes, and stricter regulatory expectations are making filter technology a key lever for safety, efficiency, and validatability.

Why filtration is becoming more demanding

Challenges in filter technology

  • Increasing product complexity

    New modalities, such as viral vectors, are placing new demands on particle control and risk assessment

  • Invisible weak points

    Leaks in filter media or seals are not visible but have a direct impact on product quality

  • Validation effort

    Integrity tests are technically demanding and must be reproducible, documented, and able to withstand regulatory scrutiny

How HEPA filters actually work

Fundamentals of filter technology

HEPA filters consist of finely structured glass fibers. Rather than simply retaining particles like a sieve, they capture them through several physical mechanisms: very small particles are captured mainly by diffusion, medium-sized particles by interception, and larger particles by inertial impaction and sieving.

Filter mechanisms HEPA filters

The most difficult particles to capture are not the smallest ones but those in the range of approximately 0.1–0.2 µm, the so-called MPPS (Most Penetrating Particle Size). Filters are classified based on this worst-case size. For all other particle sizes, filtration efficiency is higher. Particles of 5 µm and larger are completely retained.

Collection efficiency of different particle sizes
How safety is demonstrated

Regulations and filter integrity

Filters must not only work – they must be demonstrably shown to work correctly. For use in aseptic manufacturing, what matters is therefore not just a filter’s performance but also the documented evidence of that performance.

Relevant standards:

ISO 14644-1 (cleanroom classification)
ISO 14644-3 (test methods)
ISO 29463/EN 1822 (filter classification and testing)
EU GMP Annex 1 (requirements for aseptic processes)

A distinction must be made between two levels of testing: filter class and leak-tightness are verified by the manufacturer on a test rig. Once the filter is installed, the question is whether this condition has been maintained Has the filter remained undamaged during transport and installation?

Two methods are available for on-site integrity testing: the overall leak test, which assesses the overall performance of the installed filter, and scanning, which detects local leaks in the filter medium. A filter can meet overall performance requirements and still have local leaks. Scanning is therefore used for terminal filters located directly above the product.

close up of a hepa filter
  • 1. Test principle

    The integrity test compares the particle concentration upstream and downstream of the filter. A defined test aerosol (e.g., DEHS) is introduced upstream of the filter, and measurement is typically performed for particles ≥ 0.3 µm. Valid results require homogeneous distribution of the aerosol across the entire filter surface. 

  • 2. Overall leak test

    The overall leak test measures the particle concentration in the entire airflow downstream of the filter. It shows whether the installed filter delivers its overall filtration efficiency but does not pinpoint individual leaks. 

  • 3. Scanning

    During scanning, a measuring probe is passed over the filter surface. This makes it possible to locate local leaks in the filter medium or at the seal. This is critical for terminal filters because they form the last barrier before the process area. 

Why filter performance depends on system design

Design, integration, and filter concepts

Filter technology does not work in isolation but as part of an overall system. How well a filter actually protects during operation depends largely on where and how it is installed.

The first decisive factor is its position in the airflow: supply-air filters provide the system with clean air, terminal filters form the last barrier before the critical zone, and return-air or exhaust filters prevent cross-contamination and protect personnel and the environment. Airflow design is equally important. Unidirectional (laminar) flow carries any particles away from the process in a targeted way, whereas turbulent flow tends to swirl them around. Isolators add further constraints: limited space, restricted accessibility, and the question of how a filter can be tested at all once installed.

Two designs are particularly common in aseptic facilities. Both meet the requirements for particle filtration but differ in integration, testability, maintenance, and suitability for containment applications.

safe change hepa filter installed in an isolator
Which design suits which purpose

Typical filter concepts in isolator systems

  • Flat (planar) HEPA filter

    Flat (planar) HEPA filters

    • Conventional, rectangular filter elements
    • Often used as terminal filters directly above the critical zone
    • Enable uniform, unidirectional airflow across the entire work surface
    • Can be scan-tested for leaks directly, provided they are accessible

    This design is used where direct, homogeneous airflow above the process is required.

  • Filter cartridge / safe-change filter

    Filter cartridges/safe-change filters

    • Self-contained filter units
    • Used primarily in return-air and containment areas
    • Designed for replacement without releasing contamination
    • Dedicated test concepts, e.g., upstream tests or leak testing of the installation

    In higher-risk applications, such as those involving toxic substances, this controlled filter change is a central part of the overall concept.

Understanding filters in operation

Maintenance, life cycle, and underestimated factors

Filters are not static components. Integrity tests are repeated regularly, typically every 6–2 months, and filters are often replaced after 3 years, depending on material aging, seals, and process conditions. In toxic applications, contaminated filters cannot be safely tested on site. This is where safe-change concepts are essential.

What is often underestimated

  • Mechanical stress: Glass fragments and other particles can damage filter media.
  • Seal integrity and leak-tightness after maintenance: Only a repeat integrity test confirms that the filter and seal are once again in perfect condition.
  • Accessibility for testing: This should be considered as early as the selection of the filter design.
Safe change filter in an isolator
Where filter technology is heading

Outlook

The physics of filtration is well established. Today, further developments focus on the overall system: automated scanning systems for improved testability, safer and more efficient maintenance concepts, and simulation and CFD to predict airflow and particle behavior as early as the planning stage.

A well-founded approach to filter technology – from integration and validation to operation – is therefore a key building block for robust aseptic processes.

Safe change filter in a chamber

Would you like to discuss specific requirements for airflow, validation, and maintenance?

We’re happy to help. 