EU GMP Annex 1 states that the transfer of equipment and materials into and out of cleanrooms and critical zones is “one of the greatest potential sources of contamination” (4.10). Where activities that could compromise the cleanliness of these zones cannot be eliminated, appropriate controls must be implemented.
Entry into Grade A/B
Annex 1 requires a unidirectional transfer process. Wherever possible, items should be sterilized and passed in through double-ended sterilizers sealed into the wall, such as autoclaves or depyrogenation tunnels.
Where this is not possible, a validated procedure must achieve the same objective—for example, an effective transfer disinfection process, rapid transfer systems, or, for liquids and gases, a bacteria-retentive filter (4.11).
Removal
Materials, waste and environmental samples are removed from Grade A/B via a separate unidirectional route. Where this is not possible, time-based separation by procedure may be considered (4.11).
Isolators and RABS
Hazards arising from the entry or removal of items must be minimized and supported by high-capability transfer technologies or validated systems (4.18).
Items sterilized in sealed packaging
Where items sterilized in sealed packaging are transferred into Grade A, Annex 1 requires validated methods with disinfection of the outer packaging. The use of rapid transfer port technology should also be considered (8.47).
Approved materials
Only materials included on an approved list and assessed as part of transfer validation may enter Grade A/B via airlocks and pass-through hatches (4.12).
Part of the Contamination Control Strategy
Selecting and designing the transfer technology is part of the CCS (2.3) – not merely a material flow decision.