Cleanroom classes: an overview of classification and requirements

How clean is a cleanroom?

Learn more

To ensure that air purity can be measured and compared, cleanrooms are classified according to defined criteria. The classification is based on the number of airborne particles of specific sizes per cubic metre of air.

Cleanrooms are controlled environments in which the concentration of airborne particles is limited to defined limits. They are used wherever contaminants could compromise the quality, safety or functionality of a product or process – for example, in the pharmaceutical industry, medical technology, microelectronics and research.

ISO vs. GMP

Cleanroom classes in accordance with DIN EN ISO 14644-1

The international standard ISO 14644-1 classifies cleanrooms into nine classes, ranging from ISO 1 to ISO 9. ISO 1 refers to the highest level of cleanliness, whilst ISO 9 represents the lowest level of cleanliness within this classification.

The classification is based on the maximum permissible concentration of airborne particles of various sizes. The particle concentration is determined using suitable particle counters and serves as the basis for classifying air purity.

ISO classes are used in various industries, such as microelectronics, the optical industry, medical technology and research.

People wearing ppe in cleanroom
ISO vs. GMP

Cleanroom classes in accordance with Annex 1 of the EU GMP Guidelines

In the pharmaceutical manufacture of sterile medicinal products, the requirements set out in Annex 1 of the EU GMP Guidelines also apply. This distinguishes between cleanroom classes A, B, C and D, with Class A representing the highest level of cleanliness.

Unlike pure particle classification, the GMP regulations also take into account microbiological contamination and further requirements for the controlled manufacture of sterile medicinal products. The requirements depend on the specific process and the associated risk of contamination.

GMP classes are used, amongst other things, in the manufacture of sterile medicinal products. The specific classification and the required limit values must be determined on the basis of the applicable GMP guidelines and the specific application.

People wearing ppe in cleanroom

Cleanroom classes according to ISO 14644-1: Permissible particle concentrations

The following table shows the maximum permissible number of airborne particles per cubic metre of air for the various ISO cleanroom classes.

The table illustrates the significant differences in permissible particle concentration between the classes. Whilst, for example, a maximum of 3,520 particles with a size of at least 0.5 µm per cubic metre is permitted for ISO 5, the corresponding limit for ISO 8 is 3,520,000 particles.

Figures are given in particles per cubic metre of air.

Size0,1 µm0,2 µm0,3 µm0,5 µm1 µm5 µm
Class
ISO 1102
ISO 210024104
ISO 31000237102358
ISO 410’0002370102035283
ISO 5100’00023’70010’200352083229
ISO 61’000’000237’000102’00035’2008320293
ISO 7352’00083’2002930
ISO 83’520’000832’00029’300
ISO 935’200’0008’320’000293’000
Hotspot image

GMP cleanroom classes: Limit values at rest and during operation

In the pharmaceutical sector, GMP classes A to D are distinguished on the basis of specific requirements for the cleanroom environment. The following overview shows the limit values for airborne particles listed in the underlying table.

The distinction between the static and operational states is important because staff, work processes and the materials used can influence the particle concentration. Particularly in the manufacture of sterile medicinal products, the requirements for the cleanroom environment must be tailored to the specific process.

 

SizeAt rest ≥ 0,5 µmat rest ≥ 5 µmin operation ≥ 0,5 µmin opration ≥ 5 µm
Class
A3’520203’52020
B3’52029352’0002’900
C352’0002’9003’520’00029’000
D3’520’00029’000Not definedNot defined

Why is the correct cleanroom class so important?

The required cleanroom class depends on the requirements of the product and the process. The highest possible cleanliness class is not automatically necessary for every application. What is crucial is that the environment ensures the required air purity and that the relevant contamination risks are controlled.

Cleanroom classification is therefore an important part of the planning, qualification and monitoring of controlled environments.