{"id":63007,"date":"2026-11-16T15:57:02","date_gmt":"2026-11-16T14:57:02","guid":{"rendered":"https:\/\/skan.com\/?post_type=expertise&#038;p=63007"},"modified":"2026-11-17T18:29:38","modified_gmt":"2026-11-17T17:29:38","slug":"hepa-filters-in-aseptic-manufacturing-skan","status":"publish","type":"expertise","link":"https:\/\/skan.com\/en\/expertise\/pharma\/filters-aseptic-manufacturing","title":{"rendered":"Filters"},"content":{"rendered":"\r\n\r\n\n\n\r\n        \r\n        \r\n            <section  class=\"section-post-hero\">\r\n            <div class=\"container\">\r\n                <div class=\"section-post-hero-grid\">\r\n                    <div class=\"section-post-hero-media\">\r\n                        <div class=\"entry-media\">\r\n                            \r\n                                <figure class=\"\">\r\n                                                                            <img loading=\"lazy\" decoding=\"async\" width=\"2347\" height=\"1792\" src=\"https:\/\/skan.com\/wp-content\/uploads\/2026\/10\/safe-change-filter-in-isolator-1.jpeg\" class=\"attachment-full size-full\" alt=\"Safe change filter in an isolator\" srcset=\"https:\/\/skan.com\/wp-content\/uploads\/2026\/10\/safe-change-filter-in-isolator-1.jpeg 2347w, https:\/\/skan.com\/wp-content\/uploads\/2026\/10\/safe-change-filter-in-isolator-1-300x229.jpeg 300w, https:\/\/skan.com\/wp-content\/uploads\/2026\/10\/safe-change-filter-in-isolator-1-1024x782.jpeg 1024w, https:\/\/skan.com\/wp-content\/uploads\/2026\/10\/safe-change-filter-in-isolator-1-768x586.jpeg 768w, https:\/\/skan.com\/wp-content\/uploads\/2026\/10\/safe-change-filter-in-isolator-1-1536x1173.jpeg 1536w, https:\/\/skan.com\/wp-content\/uploads\/2026\/10\/safe-change-filter-in-isolator-1-2048x1564.jpeg 2048w, https:\/\/skan.com\/wp-content\/uploads\/2026\/10\/safe-change-filter-in-isolator-1-357x273.jpeg 357w\" sizes=\"auto, (max-width: 2347px) 100vw, 2347px\" \/>                                                                    <\/figure>\r\n                        <\/div>\r\n                    <\/div>\r\n                    <div class=\"section-post-hero-text\">\r\n                                                <div class=\"limiter\">\r\n                                                            <h1>Filters in aseptic manufacturing <\/h1>\r\n                                                                                        <p>Why HEPA filters determine product quality <\/p>\r\n                                                        <a class=\"link bottom anchor-link\" href=\"#nextSection\" role=\"button\">\r\n                                <span class=\"icon\"><span><span aria-hidden=\"true\"><\/span><\/span><\/span>\r\n                                <span class=\"text\">Learn more<\/span>\r\n                            <\/a>\r\n                        <\/div>\r\n                    <\/div>\r\n                <\/div>\r\n            <\/div>\r\n        <\/section>\r\n        <div aria-hidden=\"true\" id=\"nextSection\"><\/div>\r\n    \r\n    \r\n\n\n        <section  class=\"section-headers pt-default pb-default two-column\">\n        <div class=\"container\">\n                                                    <div class=\"headers-grid two-column\">\n                                            <div class=\"text any-b0\">\n                            <h4>In aseptic processes, controlled airflow is not a supporting element \u2013 it is a critical component of sterility assurance.<\/h4>\n                        <\/div>\n                                                                <div class=\"text any-b0\">\n                            <p>High-efficiency filters ensure that particles and microorganisms are reliably removed from the air before they reach the process area.<br \/>\nAt the same time, requirements are becoming increasingly stringent: new therapies, more complex processes, and stricter regulatory expectations are making filter technology a key lever for safety, efficiency, and validatability.<\/p>\n                        <\/div>\n                                    <\/div>\n                    <\/div>\n    <\/section>\n\n\n\n    <section  class=\"section-feature-grid pt-default pb-default\">\r\n        <div class=\"container\">\r\n                            <header class=\"entry-header any-b0\">\r\n                                            <h5>Why filtration is becoming more demanding <\/h5>\r\n                                                                <h2>Challenges in filter technology <\/h2>\r\n                                    <\/header>\r\n                                        <ul class=\"feature-grid-list list-reset\">\r\n                                                                                                <li>\r\n                                <div class=\"feature-grid-item any-b0\">\r\n                                    <figure class=\"icon style-svg\" aria-hidden=\"true\">\r\n                                                                                    <img loading=\"lazy\" decoding=\"async\" width=\"24\" height=\"24\" src=\"https:\/\/skan.com\/wp-content\/uploads\/2026\/09\/Exclamationmark.png\" class=\"attachment-full size-full\" alt=\"\" \/>                                                                            <\/figure>\r\n                                                                            <h3>Increasing product complexity<\/h3>\r\n                                                                                                                <p>New modalities, such as viral vectors, are placing new demands on particle control and risk assessment<\/p>\r\n                                                                    <\/div>\r\n                            <\/li>\r\n                                                                                                                        <li>\r\n                                <div class=\"feature-grid-item any-b0\">\r\n                                    <figure class=\"icon style-svg\" aria-hidden=\"true\">\r\n                                                                                    <img loading=\"lazy\" decoding=\"async\" width=\"24\" height=\"24\" src=\"https:\/\/skan.com\/wp-content\/uploads\/2026\/09\/Exclamationmark.png\" class=\"attachment-full size-full\" alt=\"\" \/>                                                                            <\/figure>\r\n                                                                            <h3>Invisible weak points<\/h3>\r\n                                                                                                                <p>Leaks in filter media or seals are not visible but have a direct impact on product quality <\/p>\r\n                                                                    <\/div>\r\n                            <\/li>\r\n                                                                                                                        <li>\r\n                                <div class=\"feature-grid-item any-b0\">\r\n                                    <figure class=\"icon style-svg\" aria-hidden=\"true\">\r\n                                                                                    <img loading=\"lazy\" decoding=\"async\" width=\"24\" height=\"24\" src=\"https:\/\/skan.com\/wp-content\/uploads\/2026\/09\/Exclamationmark.png\" class=\"attachment-full size-full\" alt=\"\" \/>                                                                            <\/figure>\r\n                                                                            <h3>Validation effort <\/h3>\r\n                                                                                                                <p>Integrity tests are technically demanding and must be reproducible, documented, and able to withstand regulatory scrutiny <\/p>\r\n                                                                    <\/div>\r\n                            <\/li>\r\n                                                            <\/ul>\r\n                    <\/div>\r\n    <\/section>\r\n\r\n\n\n    <section  class=\"section-image-text pt-default pb-default default\">\r\n        <div class=\"container\">\r\n            <div class=\"entry-grid\">\r\n                                    <div class=\"text\">\r\n                        <div class=\"text-inner\">\r\n                                                            <h5>How HEPA filters actually work <\/h5>\r\n                                                                                        <h2>Fundamentals of filter technology <\/h2>\r\n                                                        <p>HEPA filters consist of finely structured glass fibers. Rather than simply retaining particles like a sieve, they capture them through several physical mechanisms: very small particles are captured mainly by diffusion, medium-sized particles by interception, and larger particles by inertial impaction and sieving.<\/p>\n                                                                                <\/div>\r\n                    <\/div>\r\n                                                    <div class=\"image\">\r\n                        <figure class=\"\">\r\n                                                            <img loading=\"lazy\" decoding=\"async\" width=\"1472\" height=\"1600\" src=\"https:\/\/skan.com\/wp-content\/uploads\/2026\/11\/Filtration-mechanisms-hepa.png\" class=\"attachment-full size-full\" alt=\"Filter mechanisms HEPA filters\" srcset=\"https:\/\/skan.com\/wp-content\/uploads\/2026\/11\/Filtration-mechanisms-hepa.png 1472w, https:\/\/skan.com\/wp-content\/uploads\/2026\/11\/Filtration-mechanisms-hepa-276x300.png 276w, https:\/\/skan.com\/wp-content\/uploads\/2026\/11\/Filtration-mechanisms-hepa-942x1024.png 942w, https:\/\/skan.com\/wp-content\/uploads\/2026\/11\/Filtration-mechanisms-hepa-768x835.png 768w, https:\/\/skan.com\/wp-content\/uploads\/2026\/11\/Filtration-mechanisms-hepa-1413x1536.png 1413w, https:\/\/skan.com\/wp-content\/uploads\/2026\/11\/Filtration-mechanisms-hepa-357x388.png 357w\" sizes=\"auto, (max-width: 1472px) 100vw, 1472px\" \/>                                                    <\/figure>\r\n                    <\/div>\r\n                            <\/div>\r\n        <\/div>\r\n    <\/section>\r\n\n\n    <section  class=\"section-image-text pt-0 pb-default default\">\r\n        <div class=\"container\">\r\n            <div class=\"entry-grid\">\r\n                                    <div class=\"text\">\r\n                        <div class=\"text-inner\">\r\n                                                                                    <p>The most difficult particles to capture are not the smallest ones but those in the range of approximately 0.1\u20130.2 \u00b5m, the so-called MPPS (Most Penetrating Particle Size). Filters are classified based on this worst-case size. For all other particle sizes, filtration efficiency is higher. Particles of 5 \u00b5m and larger are completely retained.<\/p>\n                                                                                <\/div>\r\n                    <\/div>\r\n                                                    <div class=\"image\">\r\n                        <figure class=\"\">\r\n                                                            <img loading=\"lazy\" decoding=\"async\" width=\"1404\" height=\"844\" src=\"https:\/\/skan.com\/wp-content\/uploads\/2026\/11\/collection-efficiency-particle-size.jpg\" class=\"attachment-full size-full\" alt=\"Collection efficiency of different particle sizes\" srcset=\"https:\/\/skan.com\/wp-content\/uploads\/2026\/11\/collection-efficiency-particle-size.jpg 1404w, https:\/\/skan.com\/wp-content\/uploads\/2026\/11\/collection-efficiency-particle-size-300x180.jpg 300w, https:\/\/skan.com\/wp-content\/uploads\/2026\/11\/collection-efficiency-particle-size-1024x616.jpg 1024w, https:\/\/skan.com\/wp-content\/uploads\/2026\/11\/collection-efficiency-particle-size-768x462.jpg 768w, https:\/\/skan.com\/wp-content\/uploads\/2026\/11\/collection-efficiency-particle-size-357x215.jpg 357w\" sizes=\"auto, (max-width: 1404px) 100vw, 1404px\" \/>                                                    <\/figure>\r\n                    <\/div>\r\n                            <\/div>\r\n        <\/div>\r\n    <\/section>\r\n\n\n    <section  class=\"section-image-text pt-default pb-default default\">\r\n        <div class=\"container\">\r\n            <div class=\"entry-grid\">\r\n                                    <div class=\"text\">\r\n                        <div class=\"text-inner\">\r\n                                                            <h5>How safety is demonstrated <\/h5>\r\n                                                                                        <h2>Regulations and filter integrity <\/h2>\r\n                                                        <p>Filters must not only work \u2013 they must be demonstrably shown to work correctly. For use in aseptic manufacturing, what matters is therefore not just a filter\u2019s performance but also the documented evidence of that performance.<\/p>\n<p>Relevant standards:<\/p>\n<p>ISO 14644-1 (cleanroom classification)<br \/>\nISO 14644-3 (test methods)<br \/>\nISO 29463\/EN 1822 (filter classification and testing)<br \/>\nEU GMP Annex 1 (requirements for aseptic processes)<\/p>\n<p>A distinction must be made between two levels of testing: filter class and leak-tightness are verified by the manufacturer on a test rig. Once the filter is installed, the question is whether this condition has been maintained Has the filter remained undamaged during transport and installation?<\/p>\n<p>Two methods are available for on-site integrity testing: the overall leak test, which assesses the overall performance of the installed filter, and scanning, which detects local leaks in the filter medium. A filter can meet overall performance requirements and still have local leaks. Scanning is therefore used for terminal filters located directly above the product.<\/p>\n                                                                                <\/div>\r\n                    <\/div>\r\n                                                    <div class=\"image\">\r\n                        <figure class=\"\">\r\n                                                            <img loading=\"lazy\" decoding=\"async\" width=\"1404\" height=\"1160\" src=\"https:\/\/skan.com\/wp-content\/uploads\/2026\/09\/hepa-filter-closeup-e1791975102552.png\" class=\"attachment-full size-full\" alt=\"close up of a hepa filter\" \/>                                                    <\/figure>\r\n                    <\/div>\r\n                            <\/div>\r\n        <\/div>\r\n    <\/section>\r\n\n\n    <section  class=\"section-column-element pt-default pb-default\">\r\n        <div class=\"container\">\r\n                                        <ul class=\"column-element-list list-reset\">\r\n                                                                                                <li>\r\n                                <div class=\"column-element\">\r\n                                                                                                                <div class=\"body any-b0\">\r\n                                                                                            <h3>1. Test principle <\/h3>\r\n                                                                                        <p><span class=\"TextRun SCXW133946605 BCX8\" lang=\"EN-US\" xml:lang=\"EN-US\" data-contrast=\"auto\"><span class=\"NormalTextRun SCXW133946605 BCX8\">The integrity test compares the particle concentration upstream and downstream of the filter. A defined test aerosol (e.g., DEHS) is introduced upstream of the filter, and measurement is typically performed for particles \u2265 0.3 \u00b5m. Valid results require <\/span><span class=\"NormalTextRun ContextualSpellingAndGrammarErrorV2Themed SCXW133946605 BCX8\">homogeneous<\/span><span class=\"NormalTextRun SCXW133946605 BCX8\"> distribution of the aerosol across the entire filter surface.<\/span><\/span><span class=\"EOP Selected SCXW133946605 BCX8\" data-ccp-props=\"{}\">\u00a0<\/span><\/p>\n                                        <\/div>\r\n                                                                    <\/div>\r\n                            <\/li>\r\n                                                                                                                        <li>\r\n                                <div class=\"column-element\">\r\n                                                                                                                <div class=\"body any-b0\">\r\n                                                                                            <h3>2. Overall leak test<\/h3>\r\n                                                                                        <p><span class=\"TextRun SCXW65877614 BCX8\" lang=\"EN-US\" xml:lang=\"EN-US\" data-contrast=\"auto\"><span class=\"NormalTextRun SCXW65877614 BCX8\">The <\/span><span class=\"NormalTextRun SCXW65877614 BCX8\">overall leak test<\/span><span class=\"NormalTextRun SCXW65877614 BCX8\"> measures the particle concentration in the entire airflow downstream of the filter. It shows whether the installed filter delivers its overall filtration efficiency but does not pinpoint individual <\/span><span class=\"NormalTextRun SCXW65877614 BCX8\">leaks<\/span><span class=\"NormalTextRun SCXW65877614 BCX8\">.<\/span><\/span><span class=\"EOP Selected SCXW65877614 BCX8\" data-ccp-props=\"{}\">\u00a0<\/span><\/p>\n                                        <\/div>\r\n                                                                    <\/div>\r\n                            <\/li>\r\n                                                                                                                        <li>\r\n                                <div class=\"column-element\">\r\n                                                                                                                <div class=\"body any-b0\">\r\n                                                                                            <h3>3.  Scanning<\/h3>\r\n                                                                                        <p><span class=\"TextRun SCXW47734666 BCX8\" lang=\"EN-US\" xml:lang=\"EN-US\" data-contrast=\"auto\"><span class=\"NormalTextRun SCXW47734666 BCX8\">During scanning, a measuring probe is passed over the filter surface. This makes it possible to <\/span><span class=\"NormalTextRun SCXW47734666 BCX8\">locate<\/span><span class=\"NormalTextRun SCXW47734666 BCX8\"> local leaks in the filter medium or at the seal. This is critical for terminal filters because they form the last barrier before the process area.<\/span><\/span><span class=\"EOP Selected SCXW47734666 BCX8\" data-ccp-props=\"{}\">\u00a0<\/span><\/p>\n                                        <\/div>\r\n                                                                    <\/div>\r\n                            <\/li>\r\n                                                            <\/ul>\r\n                    <\/div>\r\n    <\/section>\r\n\r\n\r\n\n\n    <section  class=\"section-image-text pt-default pb-default default\">\r\n        <div class=\"container\">\r\n            <div class=\"entry-grid\">\r\n                                    <div class=\"text\">\r\n                        <div class=\"text-inner\">\r\n                                                            <h5>Why filter performance depends on system design <\/h5>\r\n                                                                                        <h2>Design, integration, and filter concepts <\/h2>\r\n                                                        <p>Filter technology does not work in isolation but as part of an overall system. How well a filter actually protects during operation depends largely on where and how it is installed.<\/p>\n<p>The first decisive factor is its position in the airflow: supply-air filters provide the system with clean air, terminal filters form the last barrier before the critical zone, and return-air or exhaust filters prevent cross-contamination and protect personnel and the environment. Airflow design is equally important. Unidirectional (laminar) flow carries any particles away from the process in a targeted way, whereas turbulent flow tends to swirl them around. Isolators add further constraints: limited space, restricted accessibility, and the question of how a filter can be tested at all once installed.<\/p>\n<p>Two designs are particularly common in aseptic facilities. Both meet the requirements for particle filtration but differ in integration, testability, maintenance, and suitability for containment applications.<\/p>\n                                                                                <\/div>\r\n                    <\/div>\r\n                                                    <div class=\"image\">\r\n                        <figure class=\"\">\r\n                                                            <img loading=\"lazy\" decoding=\"async\" width=\"1404\" height=\"1160\" src=\"https:\/\/skan.com\/wp-content\/uploads\/2026\/09\/design-integration-hepa-filter-e1791975877907.png\" class=\"attachment-full size-full\" alt=\"safe change hepa filter installed in an isolator\" \/>                                                    <\/figure>\r\n                    <\/div>\r\n                            <\/div>\r\n        <\/div>\r\n    <\/section>\r\n\n\n    <section  class=\"section-column-element pt-default pb-default\">\r\n        <div class=\"container\">\r\n                            <header class=\"entry-header any-b0\">\r\n                                            <h5>Which design suits which purpose <\/h5>\r\n                                                                <h2>Typical filter concepts in isolator systems <\/h2>\r\n                                    <\/header>\r\n                                        <ul class=\"column-element-list list-reset\">\r\n                                                                                                <li>\r\n                                <div class=\"column-element\">\r\n                                                                            <figure>\r\n                                            <img loading=\"lazy\" decoding=\"async\" width=\"1404\" height=\"1560\" src=\"https:\/\/skan.com\/wp-content\/uploads\/2026\/09\/hepa-filter-planar.png\" class=\"attachment-full size-full\" alt=\"Flat (planar) HEPA filter\" srcset=\"https:\/\/skan.com\/wp-content\/uploads\/2026\/09\/hepa-filter-planar.png 1404w, https:\/\/skan.com\/wp-content\/uploads\/2026\/09\/hepa-filter-planar-270x300.png 270w, https:\/\/skan.com\/wp-content\/uploads\/2026\/09\/hepa-filter-planar-922x1024.png 922w, https:\/\/skan.com\/wp-content\/uploads\/2026\/09\/hepa-filter-planar-768x853.png 768w, https:\/\/skan.com\/wp-content\/uploads\/2026\/09\/hepa-filter-planar-1382x1536.png 1382w, https:\/\/skan.com\/wp-content\/uploads\/2026\/09\/hepa-filter-planar-357x397.png 357w\" sizes=\"auto, (max-width: 1404px) 100vw, 1404px\" \/>                                        <\/figure>\r\n                                                                                                                <div class=\"body any-b0\">\r\n                                                                                            <h3>Flat (planar) HEPA filters <\/h3>\r\n                                                                                        <ul>\n<li>Conventional, rectangular filter elements<\/li>\n<li>Often used as terminal filters directly above the critical zone<\/li>\n<li>Enable uniform, unidirectional airflow across the entire work surface<\/li>\n<li>Can be scan-tested for leaks directly, provided they are accessible<\/li>\n<\/ul>\n<p>This design is used where direct, homogeneous airflow above the process is required.<\/p>\n                                        <\/div>\r\n                                                                    <\/div>\r\n                            <\/li>\r\n                                                                                                                        <li>\r\n                                <div class=\"column-element\">\r\n                                                                            <figure>\r\n                                            <img loading=\"lazy\" decoding=\"async\" width=\"1404\" height=\"1560\" src=\"https:\/\/skan.com\/wp-content\/uploads\/2026\/09\/Safe-change-filter-cartridge.png\" class=\"attachment-full size-full\" alt=\"Filter cartridge \/ safe-change filter\" srcset=\"https:\/\/skan.com\/wp-content\/uploads\/2026\/09\/Safe-change-filter-cartridge.png 1404w, https:\/\/skan.com\/wp-content\/uploads\/2026\/09\/Safe-change-filter-cartridge-270x300.png 270w, https:\/\/skan.com\/wp-content\/uploads\/2026\/09\/Safe-change-filter-cartridge-922x1024.png 922w, https:\/\/skan.com\/wp-content\/uploads\/2026\/09\/Safe-change-filter-cartridge-768x853.png 768w, https:\/\/skan.com\/wp-content\/uploads\/2026\/09\/Safe-change-filter-cartridge-1382x1536.png 1382w, https:\/\/skan.com\/wp-content\/uploads\/2026\/09\/Safe-change-filter-cartridge-357x397.png 357w\" sizes=\"auto, (max-width: 1404px) 100vw, 1404px\" \/>                                        <\/figure>\r\n                                                                                                                <div class=\"body any-b0\">\r\n                                                                                            <h3>Filter cartridges\/safe-change filters <\/h3>\r\n                                                                                        <ul>\n<li>Self-contained filter units<\/li>\n<li>Used primarily in return-air and containment areas<\/li>\n<li>Designed for replacement without releasing contamination<\/li>\n<li>Dedicated test concepts, e.g., upstream tests or leak testing of the installation<\/li>\n<\/ul>\n<p>In higher-risk applications, such as those involving toxic substances, this controlled filter change is a central part of the overall concept.<\/p>\n                                        <\/div>\r\n                                                                    <\/div>\r\n                            <\/li>\r\n                                                            <\/ul>\r\n                    <\/div>\r\n    <\/section>\r\n\r\n\r\n\n\n    <section  class=\"section-image-text pt-default pb-default default\">\r\n        <div class=\"container\">\r\n            <div class=\"entry-grid\">\r\n                                    <div class=\"text\">\r\n                        <div class=\"text-inner\">\r\n                                                            <h5>Understanding filters in operation <\/h5>\r\n                                                                                        <h2>Maintenance, life cycle, and underestimated factors <\/h2>\r\n                                                        <p>Filters are not static components. Integrity tests are repeated regularly, typically every 6\u20132 months, and filters are often replaced after 3 years, depending on material aging, seals, and process conditions. In toxic applications, contaminated filters cannot be safely tested on site. This is where safe-change concepts are essential.<\/p>\n<p><strong>What is often underestimated <\/strong><\/p>\n<ul>\n<li>Mechanical stress: Glass fragments and other particles can damage filter media.<\/li>\n<li>Seal integrity and leak-tightness after maintenance: Only a repeat integrity test confirms that the filter and seal are once again in perfect condition.<\/li>\n<li>Accessibility for testing: This should be considered as early as the selection of the filter design.<\/li>\n<\/ul>\n                                                                                <\/div>\r\n                    <\/div>\r\n                                                    <div class=\"image\">\r\n                        <figure class=\"\">\r\n                                                            <img loading=\"lazy\" decoding=\"async\" width=\"2347\" height=\"1792\" src=\"https:\/\/skan.com\/wp-content\/uploads\/2026\/10\/safe-change-filter-in-isolator-e1792047711497.jpeg\" class=\"attachment-full size-full\" alt=\"Safe change filter in an isolator\" \/>                                                    <\/figure>\r\n                    <\/div>\r\n                            <\/div>\r\n        <\/div>\r\n    <\/section>\r\n\n\n    <section  class=\"section-image-text pt-default pb-default default\">\r\n        <div class=\"container\">\r\n            <div class=\"entry-grid\">\r\n                                    <div class=\"text\">\r\n                        <div class=\"text-inner\">\r\n                                                            <h5>Where filter technology is heading <\/h5>\r\n                                                                                        <h2>Outlook <\/h2>\r\n                                                        <p>The physics of filtration is well established. Today, further developments focus on the overall system: automated scanning systems for improved testability, safer and more efficient maintenance concepts, and simulation and CFD to predict airflow and particle behavior as early as the planning stage.<\/p>\n<p>A well-founded approach to filter technology \u2013 from integration and validation to operation \u2013 is therefore a key building block for robust aseptic processes.<\/p>\n                                                                                <\/div>\r\n                    <\/div>\r\n                                                    <div class=\"image\">\r\n                        <figure class=\"\">\r\n                                                            <img loading=\"lazy\" decoding=\"async\" width=\"1919\" height=\"1281\" src=\"https:\/\/skan.com\/wp-content\/uploads\/2026\/10\/safe-change-filter-in-chamber-1-e1792054626199.jpeg\" class=\"attachment-full size-full\" alt=\"Safe change filter in a chamber\" \/>                                                    <\/figure>\r\n                    <\/div>\r\n                            <\/div>\r\n        <\/div>\r\n    <\/section>\r\n\n\n    <section id=\"contact\" class=\"section-contact-teaser pt-default pb-default\">\r\n        <div class=\"contact-teaser-block viewport-section\">\r\n            <div class=\"container\">\r\n                                    <div class=\"limiter any-b0\">\r\n                                                    <h2>Would you like to discuss specific requirements for airflow, validation, and maintenance? <\/h2>\r\n                                                <p><span class=\"TextRun SCXW201969940 BCX8\" lang=\"EN-US\" xml:lang=\"EN-US\" data-contrast=\"auto\"><span class=\"NormalTextRun SCXW201969940 BCX8\">We\u2019re<\/span><span class=\"NormalTextRun SCXW201969940 BCX8\"> happy to help.<\/span><\/span><span class=\"EOP Selected SCXW201969940 BCX8\" data-ccp-props=\"{}\">\u00a0<\/span><\/p>\n                    <\/div>\r\n                                                    <ul class=\"contact-teaser-list list-reset\">\r\n                                                                                <li>\r\n                                <a href=\"https:\/\/skan.com\/en\/contact?pid=63007\" target=\"_self\">\r\n                                                                        \r\n                                                                            <span class=\"text\">Contact<\/span>\r\n                                    \r\n                                    <span aria-hidden=\"true\"><\/span>\r\n                                <\/a>\r\n                            <\/li>\r\n                                                                                <li>\r\n                                <a href=\"https:\/\/skan.com\/en\/expertise\/pharma\/isolator-technology?pid=63007\" target=\"_self\">\r\n                                                                        \r\n                                                                            <span class=\"text\">Read more about isolator technology<\/span>\r\n                                    \r\n                                    <span aria-hidden=\"true\"><\/span>\r\n                                <\/a>\r\n                            <\/li>\r\n                                            <\/ul>\r\n                            <\/div>\r\n        <\/div>\r\n    <\/section>\r\n","protected":false},"featured_media":0,"template":"","meta":{"_acf_changed":false,"inline_featured_image":false,"footnotes":""},"class_list":["post-63007","expertise","type-expertise","status-publish","hentry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Filters in aseptic processes | SKAN<\/title>\n<meta name=\"description\" content=\"How HEPA filters work, how filter integrity is verified by scan testing, and what matters for integration and maintenance in isolators.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/skan.com\/en\/expertise\/pharma\/filters-aseptic-manufacturing\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Filters in aseptic processes | SKAN\" \/>\n<meta property=\"og:description\" content=\"How HEPA filters work, how filter integrity is verified by scan testing, and what matters for integration and maintenance in isolators.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/skan.com\/en\/expertise\/pharma\/filters-aseptic-manufacturing\" \/>\n<meta property=\"og:site_name\" content=\"SKAN\" \/>\n<meta property=\"article:modified_time\" content=\"2026-11-17T17:29:38+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/skan.com\\\/en\\\/expertise\\\/pharma\\\/filters-aseptic-manufacturing\",\"url\":\"https:\\\/\\\/skan.com\\\/en\\\/expertise\\\/pharma\\\/filters-aseptic-manufacturing\",\"name\":\"Filters in aseptic processes | SKAN\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/skan.com\\\/en\\\/#website\"},\"datePublished\":\"2026-11-16T14:57:02+00:00\",\"dateModified\":\"2026-11-17T17:29:38+00:00\",\"description\":\"How HEPA filters work, how filter integrity is verified by scan testing, and what matters for integration and maintenance in isolators.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/skan.com\\\/en\\\/expertise\\\/pharma\\\/filters-aseptic-manufacturing#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/skan.com\\\/en\\\/expertise\\\/pharma\\\/filters-aseptic-manufacturing\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/skan.com\\\/en\\\/expertise\\\/pharma\\\/filters-aseptic-manufacturing#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Startseite\",\"item\":\"https:\\\/\\\/skan.com\\\/en\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Filters\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/skan.com\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/skan.com\\\/en\\\/\",\"name\":\"SKAN\",\"description\":\"Ihr Partner f\u00fcr Forschungslaboratorien\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/skan.com\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Filters in aseptic processes | SKAN","description":"How HEPA filters work, how filter integrity is verified by scan testing, and what matters for integration and maintenance in isolators.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/skan.com\/en\/expertise\/pharma\/filters-aseptic-manufacturing","og_locale":"en_US","og_type":"article","og_title":"Filters in aseptic processes | SKAN","og_description":"How HEPA filters work, how filter integrity is verified by scan testing, and what matters for integration and maintenance in isolators.","og_url":"https:\/\/skan.com\/en\/expertise\/pharma\/filters-aseptic-manufacturing","og_site_name":"SKAN","article_modified_time":"2026-11-17T17:29:38+00:00","twitter_card":"summary_large_image","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/skan.com\/en\/expertise\/pharma\/filters-aseptic-manufacturing","url":"https:\/\/skan.com\/en\/expertise\/pharma\/filters-aseptic-manufacturing","name":"Filters in aseptic processes | SKAN","isPartOf":{"@id":"https:\/\/skan.com\/en\/#website"},"datePublished":"2026-11-16T14:57:02+00:00","dateModified":"2026-11-17T17:29:38+00:00","description":"How HEPA filters work, how filter integrity is verified by scan testing, and what matters for integration and maintenance in isolators.","breadcrumb":{"@id":"https:\/\/skan.com\/en\/expertise\/pharma\/filters-aseptic-manufacturing#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/skan.com\/en\/expertise\/pharma\/filters-aseptic-manufacturing"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/skan.com\/en\/expertise\/pharma\/filters-aseptic-manufacturing#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Startseite","item":"https:\/\/skan.com\/en"},{"@type":"ListItem","position":2,"name":"Filters"}]},{"@type":"WebSite","@id":"https:\/\/skan.com\/en\/#website","url":"https:\/\/skan.com\/en\/","name":"SKAN","description":"Ihr Partner f\u00fcr Forschungslaboratorien","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/skan.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"}]}},"permalink_manager":null,"_links":{"self":[{"href":"https:\/\/skan.com\/en\/wp-json\/wp\/v2\/expertise\/63007","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/skan.com\/en\/wp-json\/wp\/v2\/expertise"}],"about":[{"href":"https:\/\/skan.com\/en\/wp-json\/wp\/v2\/types\/expertise"}],"version-history":[{"count":7,"href":"https:\/\/skan.com\/en\/wp-json\/wp\/v2\/expertise\/63007\/revisions"}],"predecessor-version":[{"id":63541,"href":"https:\/\/skan.com\/en\/wp-json\/wp\/v2\/expertise\/63007\/revisions\/63541"}],"wp:attachment":[{"href":"https:\/\/skan.com\/en\/wp-json\/wp\/v2\/media?parent=63007"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}