{"id":62926,"date":"2026-11-02T15:31:56","date_gmt":"2026-11-02T14:31:56","guid":{"rendered":"https:\/\/skan.com\/?post_type=expertise&#038;p=62926"},"modified":"2026-11-17T17:44:15","modified_gmt":"2026-11-17T16:44:15","slug":"h%e2%82%82o%e2%82%82-catalysts-in-isolators","status":"publish","type":"expertise","link":"https:\/\/skan.com\/en\/expertise\/pharma\/catalysts","title":{"rendered":"Catalysts"},"content":{"rendered":"\r\n\r\n\n\n\r\n        \r\n        \r\n            <section  class=\"section-post-hero\">\r\n            <div class=\"container\">\r\n                <div class=\"section-post-hero-grid\">\r\n                    <div class=\"section-post-hero-media\">\r\n                        <div class=\"entry-media\">\r\n                            \r\n                                <figure class=\"\">\r\n                                                                            <img loading=\"lazy\" decoding=\"async\" width=\"1404\" height=\"1760\" src=\"https:\/\/skan.com\/wp-content\/uploads\/2026\/08\/catalyst-h2o2-decomposition.png\" class=\"attachment-full size-full\" alt=\"Close up of catalytic converter surface\" srcset=\"https:\/\/skan.com\/wp-content\/uploads\/2026\/08\/catalyst-h2o2-decomposition.png 1404w, https:\/\/skan.com\/wp-content\/uploads\/2026\/08\/catalyst-h2o2-decomposition-239x300.png 239w, https:\/\/skan.com\/wp-content\/uploads\/2026\/08\/catalyst-h2o2-decomposition-817x1024.png 817w, https:\/\/skan.com\/wp-content\/uploads\/2026\/08\/catalyst-h2o2-decomposition-768x963.png 768w, https:\/\/skan.com\/wp-content\/uploads\/2026\/08\/catalyst-h2o2-decomposition-1225x1536.png 1225w, https:\/\/skan.com\/wp-content\/uploads\/2026\/08\/catalyst-h2o2-decomposition-335x420.png 335w\" sizes=\"auto, (max-width: 1404px) 100vw, 1404px\" \/>                                                                    <\/figure>\r\n                        <\/div>\r\n                    <\/div>\r\n                    <div class=\"section-post-hero-text\">\r\n                                                <div class=\"limiter\">\r\n                                                            <h1>Catalysts<\/h1>\r\n                                                                                        <p>Efficient H\u2082O\u2082 reduction: The key to safe and cost-effective processes<\/p>\r\n                                                        <a class=\"link bottom anchor-link\" href=\"#nextSection\" role=\"button\">\r\n                                <span class=\"icon\"><span><span aria-hidden=\"true\"><\/span><\/span><\/span>\r\n                                <span class=\"text\">Learn more<\/span>\r\n                            <\/a>\r\n                        <\/div>\r\n                    <\/div>\r\n                <\/div>\r\n            <\/div>\r\n        <\/section>\r\n        <div aria-hidden=\"true\" id=\"nextSection\"><\/div>\r\n    \r\n    \r\n\n\n        <section  class=\"section-headers pt-default pb-default two-column\">\n        <div class=\"container\">\n                                                    <div class=\"headers-grid two-column\">\n                                            <div class=\"text any-b0\">\n                            <h4>Shorter aeration. More stable processes. A safer working environment.<\/h4>\n                        <\/div>\n                                                                <div class=\"text any-b0\">\n                            <p>In aseptic manufacturing environments, hydrogen peroxide (H\u2082O\u2082) is an established standard for bio-decontamination. One of the challenges, however, begins afterward: breaking down H\u2082O\u2082 completely and in a controlled manner without slowing processes or creating risks for product and personnel.<br \/>\nCatalysts play a central role here \u2013 as an invisible yet critical component of efficient decontamination and aeration concepts.<\/p>\n                        <\/div>\n                                    <\/div>\n                    <\/div>\n    <\/section>\n\n\n\n    <section  class=\"section-image-text pt-default pb-default reverse default\">\r\n        <div class=\"container\">\r\n            <div class=\"entry-grid\">\r\n                                    <div class=\"text\">\r\n                        <div class=\"text-inner\">\r\n                                                            <h5>Where the real challenge begins<\/h5>\r\n                                                                                        <h2>Aeration, exposure limits, and cycle times<\/h2>\r\n                                                                                                                    <ul class=\"feature-list list-reset\">\r\n                                                                                                                                                                <li>\r\n                                                <div class=\"feature-item\">\r\n                                                                                                                                                                <div class=\"any-b0\">\r\n                                                            <h3>Long aeration times<\/h3>\n<p>After decontamination, the H\u2082O\u2082 concentration must drop quickly to safe levels. The aeration phase is often the bottleneck of the entire cycle.<\/p>\n                                                        <\/div>\r\n                                                                                                    <\/div>\r\n                                            <\/li>\r\n                                                                                                                                                                                                        <li>\r\n                                                <div class=\"feature-item\">\r\n                                                                                                                                                                <div class=\"any-b0\">\r\n                                                            <h3>Balancing safety and efficiency<\/h3>\n<p>High H\u2082O\u2082 concentrations and conventional airflow concepts with large air volumes ensure effective decontamination, but they also extend aeration, increase energy consumption, and delay the return to production.<\/p>\n                                                        <\/div>\r\n                                                                                                    <\/div>\r\n                                            <\/li>\r\n                                                                                                                                                                                                        <li>\r\n                                                <div class=\"feature-item\">\r\n                                                                                                                                                                <div class=\"any-b0\">\r\n                                                            <h3>Regulatory requirements<\/h3>\n<p>Exposure limits (e.g., in the ppm range) must be met reliably and reproducibly.<\/p>\n                                                        <\/div>\r\n                                                                                                    <\/div>\r\n                                            <\/li>\r\n                                                                                                                                                                                                        <li>\r\n                                                <div class=\"feature-item\">\r\n                                                                                                                                                                <div class=\"any-b0\">\r\n                                                            <h3>Material and process compatibility<\/h3>\n<p>Residual H\u2082O\u2082 can affect products, surfaces, and processes.<\/p>\n                                                        <\/div>\r\n                                                                                                    <\/div>\r\n                                            <\/li>\r\n                                                                                                            <\/ul>\r\n                                                                                <\/div>\r\n                    <\/div>\r\n                                                    <div class=\"image\">\r\n                        <figure class=\"\">\r\n                                                            <img loading=\"lazy\" decoding=\"async\" width=\"1129\" height=\"1067\" src=\"https:\/\/skan.com\/wp-content\/uploads\/2026\/10\/air-handling-isolator-e1791893124857.png\" class=\"attachment-full size-full\" alt=\"Air handling in an isolator\" \/>                                                    <\/figure>\r\n                    <\/div>\r\n                            <\/div>\r\n        <\/div>\r\n    <\/section>\r\n\n\n    <section  class=\"section-image-text pt-default pb-default default\">\r\n        <div class=\"container\">\r\n            <div class=\"entry-grid\">\r\n                                    <div class=\"text\">\r\n                        <div class=\"text-inner\">\r\n                                                            <h5>How catalysts break down H\u2082O\u2082<\/h5>\r\n                                                                                        <h2>From chemical principle to process performance<\/h2>\r\n                                                        <p>Without catalysis, H\u2082O\u2082 decomposes too slowly. The breakdown then depends mainly on how much air is passed through the system \u2013 a time-consuming and energy-intensive approach.<\/p>\n<p>Catalysts accelerate decomposition by lowering the required activation energy. In the process, H\u2082O\u2082 is selectively converted into water and oxygen:<\/p>\n<p><strong>2 H\u2082O\u2082 \u2192 2 H\u2082O + O\u2082<\/strong><\/p>\n<p>The catalyst itself remains chemically unchanged. Industrial applications rely on heterogeneous catalysis: gaseous H\u2082O\u2082 reacts on the surface of a solid catalyst. How efficiently this happens therefore depends heavily on the surface area and material structure \u2013 and on how the air is directed past that surface.<\/p>\n<p>This results in a central design principle:<br \/>\n<strong>Maximum surface area + controlled airflow = maximum efficiency<\/strong><\/p>\n<p>However, catalysts act only on the H\u2082O\u2082 in the air. H\u2082O\u2082 that has penetrated materials such as gloves, seals, or plastics during decontamination off-gasses only slowly. Even with high-performance catalysis, material selection therefore remains an important factor in aeration time.<\/p>\n                                                                                <\/div>\r\n                    <\/div>\r\n                                                    <div class=\"image\">\r\n                        <figure class=\"\">\r\n                                                            <img loading=\"lazy\" decoding=\"async\" width=\"1449\" height=\"1068\" src=\"https:\/\/skan.com\/wp-content\/uploads\/2026\/10\/catalyst-h2o2-decomposition-nanox-e1791893352457.png\" class=\"attachment-full size-full\" alt=\"H2O2 decomposition by nanox catalyst\" \/>                                                    <\/figure>\r\n                    <\/div>\r\n                            <\/div>\r\n        <\/div>\r\n    <\/section>\r\n\n\n    <section  class=\"section-image-text pt-default pb-default default\">\r\n        <div class=\"container\">\r\n            <div class=\"entry-grid\">\r\n                                    <div class=\"text\">\r\n                        <div class=\"text-inner\">\r\n                                                            <h5>What sets modern catalysts apart<\/h5>\r\n                                                                                        <h2>Materials, stability, and integration<\/h2>\r\n                                                        <p>Current developments show a clear trend away from conventional materials toward nanostructured systems. Their key characteristics include:<\/p>\n<ul>\n<li>Metal-based nanostructures for high reactivity<\/li>\n<li>Porous coatings on ceramic substrates with a large specific surface area (BET value &gt; 200 m\u00b2\/g)<\/li>\n<li>Moisture management to keep humidity from blocking the active surface<\/li>\n<li>Low pressure drop for energy-efficient airflow<\/li>\n<\/ul>\n<p>This enables faster H\u2082O\u2082 breakdown with lower air volumes and more compact systems. And this performance is maintained over the long term: in a stress test with 50 kg of H\u2082O\u2082 (49.5% w\/w) at 600 m\u00b3\/h, the decomposition rate decreased by only approx. 0.015%.<\/p>\n<p>What determines effectiveness in operation, however, is not just the material but how it is integrated into the system \u2013 in particular, volumetric flow rate, contact time, pressure drop, and position in the airflow.<\/p>\n                                                                                <\/div>\r\n                    <\/div>\r\n                                                    <div class=\"image\">\r\n                        <figure class=\"\">\r\n                                                            <img loading=\"lazy\" decoding=\"async\" width=\"1404\" height=\"1160\" src=\"https:\/\/skan.com\/wp-content\/uploads\/2026\/08\/catalytic-converter-isolator-e1792066985694.png\" class=\"attachment-full size-full\" alt=\"Catalytic converter in isolator\" \/>                                                    <\/figure>\r\n                    <\/div>\r\n                            <\/div>\r\n        <\/div>\r\n    <\/section>\r\n\n\n    <section  class=\"section-feature-grid pt-default pb-default\">\r\n        <div class=\"container\">\r\n                            <header class=\"entry-header any-b0\">\r\n                                            <h5>Where catalysts make the difference<\/h5>\r\n                                                                <h2>Applications at a glance<\/h2>\r\n                                    <\/header>\r\n                                        <ul class=\"feature-grid-list list-reset\">\r\n                                                                                                <li>\r\n                                <div class=\"feature-grid-item any-b0\">\r\n                                    <figure class=\"icon style-svg\" aria-hidden=\"true\">\r\n                                                                                    <svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"24\" height=\"24\" viewBox=\"0 0 24 24\" fill=\"none\"><rect x=\"0.5\" y=\"0.5\" width=\"23\" height=\"23\" rx=\"11.5\" fill=\"#E2ECF0\" stroke=\"#C5D9E1\"\/><path d=\"M7 11.7308L10.5 15.5L17 8.5\" stroke=\"#004682\" stroke-width=\"1.5\" stroke-linecap=\"square\"\/><\/svg>\r\n                                                                            <\/figure>\r\n                                                                            <h3>Isolators for aseptic manufacturing<\/h3>\r\n                                                                                                                <p>Shorter aeration translates directly into more production time.<\/p>\r\n                                                                    <\/div>\r\n                            <\/li>\r\n                                                                                                                        <li>\r\n                                <div class=\"feature-grid-item any-b0\">\r\n                                    <figure class=\"icon style-svg\" aria-hidden=\"true\">\r\n                                                                                    <svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"24\" height=\"24\" viewBox=\"0 0 24 24\" fill=\"none\"><rect x=\"0.5\" y=\"0.5\" width=\"23\" height=\"23\" rx=\"11.5\" fill=\"#E2ECF0\" stroke=\"#C5D9E1\"\/><path d=\"M7 11.7308L10.5 15.5L17 8.5\" stroke=\"#004682\" stroke-width=\"1.5\" stroke-linecap=\"square\"\/><\/svg>\r\n                                                                            <\/figure>\r\n                                                                            <h3>Fill-finish lines<\/h3>\r\n                                                                                                                <p>Every hour of downtime is especially costly here.<\/p>\r\n                                                                    <\/div>\r\n                            <\/li>\r\n                                                                                                                        <li>\r\n                                <div class=\"feature-grid-item any-b0\">\r\n                                    <figure class=\"icon style-svg\" aria-hidden=\"true\">\r\n                                                                                    <svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"24\" height=\"24\" viewBox=\"0 0 24 24\" fill=\"none\"><rect x=\"0.5\" y=\"0.5\" width=\"23\" height=\"23\" rx=\"11.5\" fill=\"#E2ECF0\" stroke=\"#C5D9E1\"\/><path d=\"M7 11.7308L10.5 15.5L17 8.5\" stroke=\"#004682\" stroke-width=\"1.5\" stroke-linecap=\"square\"\/><\/svg>\r\n                                                                            <\/figure>\r\n                                                                            <h3>Sterility testing systems<\/h3>\r\n                                                                                                                <p>Residual H\u2082O\u2082 can inhibit microbial growth and thus skew test results.<\/p>\r\n                                                                    <\/div>\r\n                            <\/li>\r\n                                                                                                                        <li>\r\n                                <div class=\"feature-grid-item any-b0\">\r\n                                    <figure class=\"icon style-svg\" aria-hidden=\"true\">\r\n                                                                                    <svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"24\" height=\"24\" viewBox=\"0 0 24 24\" fill=\"none\"><rect x=\"0.5\" y=\"0.5\" width=\"23\" height=\"23\" rx=\"11.5\" fill=\"#E2ECF0\" stroke=\"#C5D9E1\"\/><path d=\"M7 11.7308L10.5 15.5L17 8.5\" stroke=\"#004682\" stroke-width=\"1.5\" stroke-linecap=\"square\"\/><\/svg>\r\n                                                                            <\/figure>\r\n                                                                            <h3>Decontamination airlocks<\/h3>\r\n                                                                                                                <p>Short cycles are a prerequisite for efficient material flow.<\/p>\r\n                                                                    <\/div>\r\n                            <\/li>\r\n                                                                                                                        <li>\r\n                                <div class=\"feature-grid-item any-b0\">\r\n                                    <figure class=\"icon style-svg\" aria-hidden=\"true\">\r\n                                                                                    <svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"24\" height=\"24\" viewBox=\"0 0 24 24\" fill=\"none\"><rect x=\"0.5\" y=\"0.5\" width=\"23\" height=\"23\" rx=\"11.5\" fill=\"#E2ECF0\" stroke=\"#C5D9E1\"\/><path d=\"M7 11.7308L10.5 15.5L17 8.5\" stroke=\"#004682\" stroke-width=\"1.5\" stroke-linecap=\"square\"\/><\/svg>\r\n                                                                            <\/figure>\r\n                                                                            <h3>ATMPs and clinical manufacturing<\/h3>\r\n                                                                                                                <p>Frequent product changeovers and sensitive products require fast, thorough aeration.<\/p>\r\n                                                                    <\/div>\r\n                            <\/li>\r\n                                                                                                                        <li>\r\n                                <div class=\"feature-grid-item any-b0\">\r\n                                    <figure class=\"icon style-svg\" aria-hidden=\"true\">\r\n                                                                                    <svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"24\" height=\"24\" viewBox=\"0 0 24 24\" fill=\"none\"><rect x=\"0.5\" y=\"0.5\" width=\"23\" height=\"23\" rx=\"11.5\" fill=\"#E2ECF0\" stroke=\"#C5D9E1\"\/><path d=\"M7 11.7308L10.5 15.5L17 8.5\" stroke=\"#004682\" stroke-width=\"1.5\" stroke-linecap=\"square\"\/><\/svg>\r\n                                                                            <\/figure>\r\n                                                                            <h3>Highly potent compounds and modular facilities<\/h3>\r\n                                                                                                                <p>Closed, compact systems require little or no external exhaust infrastructure.<\/p>\r\n                                                                    <\/div>\r\n                            <\/li>\r\n                                                            <\/ul>\r\n                    <\/div>\r\n    <\/section>\r\n\r\n\n\n    <section  class=\"section-image-text pt-default pb-default default\">\r\n        <div class=\"container\">\r\n            <div class=\"entry-grid\">\r\n                                    <div class=\"text\">\r\n                        <div class=\"text-inner\">\r\n                                                            <h5>What this means for operations<\/h5>\r\n                                                                                        <h2>Cycle time, safety, and efficiency<\/h2>\r\n                                                        <p>When properly designed, catalysts have a direct impact on process performance: cycle times decrease, exposure limits are met reproducibly, and facility concepts become simpler \u2013 in some cases eliminating the need for external exhaust systems altogether \u2013 while reduced air volumes and low pressure drop cut energy consumption.<\/p>\n<p>As requirements for flexibility, throughput, energy efficiency, and containment continue to rise, catalysts are evolving from a supporting component into a key lever for safe and cost-effective decontamination processes. SKAN pursues this approach with its nanox technology, which is integrated directly into its systems.<\/p>\n                                                                                <\/div>\r\n                    <\/div>\r\n                                                    <div class=\"image\">\r\n                        <figure class=\"\">\r\n                                                            <img loading=\"lazy\" decoding=\"async\" width=\"1404\" height=\"1160\" src=\"https:\/\/skan.com\/wp-content\/uploads\/2026\/08\/catalytic-converter-production-skan.png\" class=\"attachment-full size-full\" alt=\"Man builds catalytic converter in assemly hall\" srcset=\"https:\/\/skan.com\/wp-content\/uploads\/2026\/08\/catalytic-converter-production-skan.png 1404w, https:\/\/skan.com\/wp-content\/uploads\/2026\/08\/catalytic-converter-production-skan-300x248.png 300w, https:\/\/skan.com\/wp-content\/uploads\/2026\/08\/catalytic-converter-production-skan-1024x846.png 1024w, https:\/\/skan.com\/wp-content\/uploads\/2026\/08\/catalytic-converter-production-skan-768x635.png 768w, https:\/\/skan.com\/wp-content\/uploads\/2026\/08\/catalytic-converter-production-skan-357x295.png 357w\" sizes=\"auto, (max-width: 1404px) 100vw, 1404px\" \/>                                                    <\/figure>\r\n                    <\/div>\r\n                            <\/div>\r\n        <\/div>\r\n    <\/section>\r\n\n\n    <section id=\"contact\" class=\"section-contact-teaser pt-default pb-default\">\r\n        <div class=\"contact-teaser-block viewport-section\">\r\n            <div class=\"container\">\r\n                                    <div class=\"limiter any-b0\">\r\n                                                    <h2>Understand your decontamination processes in detail.<\/h2>\r\n                                                <p>Talk to our experts about your specific application.<\/p>\n                    <\/div>\r\n                                                    <ul class=\"contact-teaser-list list-reset\">\r\n                                                                                <li>\r\n                                <a href=\"https:\/\/skan.com\/en\/contact?pid=62926\" target=\"_self\">\r\n                                                                        \r\n                                                                            <span class=\"text\">Contact<\/span>\r\n                                    \r\n                                    <span aria-hidden=\"true\"><\/span>\r\n                                <\/a>\r\n                            <\/li>\r\n                                                                                <li>\r\n                                <a href=\"https:\/\/skan.com\/en\/expertise\/pharma\/isolator-technology?pid=62926\" target=\"_self\">\r\n                                                                        \r\n                                                                            <span class=\"text\">More about isolator technology<\/span>\r\n                                    \r\n                                    <span aria-hidden=\"true\"><\/span>\r\n                                <\/a>\r\n                            <\/li>\r\n                                            <\/ul>\r\n                            <\/div>\r\n        <\/div>\r\n    <\/section>\r\n","protected":false},"featured_media":0,"template":"","meta":{"_acf_changed":false,"inline_featured_image":false,"footnotes":""},"class_list":["post-62926","expertise","type-expertise","status-publish","hentry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Catalysts - SKAN<\/title>\n<meta name=\"description\" content=\"Discover how H\u2082O\u2082 catalysts support efficient peroxide removal, shorter aeration times and reliable process performance in isolator systems.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/skan.com\/en\/expertise\/pharma\/catalysts\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Catalysts - SKAN\" \/>\n<meta property=\"og:description\" content=\"Discover how H\u2082O\u2082 catalysts support efficient peroxide removal, shorter aeration times and reliable process performance in isolator systems.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/skan.com\/en\/expertise\/pharma\/catalysts\" \/>\n<meta property=\"og:site_name\" content=\"SKAN\" \/>\n<meta property=\"article:modified_time\" content=\"2026-11-17T16:44:15+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/skan.com\\\/en\\\/expertise\\\/pharma\\\/catalysts\",\"url\":\"https:\\\/\\\/skan.com\\\/en\\\/expertise\\\/pharma\\\/catalysts\",\"name\":\"Catalysts - SKAN\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/skan.com\\\/en\\\/#website\"},\"datePublished\":\"2026-11-02T14:31:56+00:00\",\"dateModified\":\"2026-11-17T16:44:15+00:00\",\"description\":\"Discover how H\u2082O\u2082 catalysts support efficient peroxide removal, shorter aeration times and reliable process performance in isolator systems.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/skan.com\\\/en\\\/expertise\\\/pharma\\\/catalysts#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/skan.com\\\/en\\\/expertise\\\/pharma\\\/catalysts\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/skan.com\\\/en\\\/expertise\\\/pharma\\\/catalysts#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Startseite\",\"item\":\"https:\\\/\\\/skan.com\\\/en\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Catalysts\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/skan.com\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/skan.com\\\/en\\\/\",\"name\":\"SKAN\",\"description\":\"Ihr Partner f\u00fcr Forschungslaboratorien\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/skan.com\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Catalysts - SKAN","description":"Discover how H\u2082O\u2082 catalysts support efficient peroxide removal, shorter aeration times and reliable process performance in isolator systems.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/skan.com\/en\/expertise\/pharma\/catalysts","og_locale":"en_US","og_type":"article","og_title":"Catalysts - SKAN","og_description":"Discover how H\u2082O\u2082 catalysts support efficient peroxide removal, shorter aeration times and reliable process performance in isolator systems.","og_url":"https:\/\/skan.com\/en\/expertise\/pharma\/catalysts","og_site_name":"SKAN","article_modified_time":"2026-11-17T16:44:15+00:00","twitter_card":"summary_large_image","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/skan.com\/en\/expertise\/pharma\/catalysts","url":"https:\/\/skan.com\/en\/expertise\/pharma\/catalysts","name":"Catalysts - SKAN","isPartOf":{"@id":"https:\/\/skan.com\/en\/#website"},"datePublished":"2026-11-02T14:31:56+00:00","dateModified":"2026-11-17T16:44:15+00:00","description":"Discover how H\u2082O\u2082 catalysts support efficient peroxide removal, shorter aeration times and reliable process performance in isolator systems.","breadcrumb":{"@id":"https:\/\/skan.com\/en\/expertise\/pharma\/catalysts#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/skan.com\/en\/expertise\/pharma\/catalysts"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/skan.com\/en\/expertise\/pharma\/catalysts#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Startseite","item":"https:\/\/skan.com\/en"},{"@type":"ListItem","position":2,"name":"Catalysts"}]},{"@type":"WebSite","@id":"https:\/\/skan.com\/en\/#website","url":"https:\/\/skan.com\/en\/","name":"SKAN","description":"Ihr Partner f\u00fcr Forschungslaboratorien","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/skan.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"}]}},"permalink_manager":null,"_links":{"self":[{"href":"https:\/\/skan.com\/en\/wp-json\/wp\/v2\/expertise\/62926","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/skan.com\/en\/wp-json\/wp\/v2\/expertise"}],"about":[{"href":"https:\/\/skan.com\/en\/wp-json\/wp\/v2\/types\/expertise"}],"version-history":[{"count":7,"href":"https:\/\/skan.com\/en\/wp-json\/wp\/v2\/expertise\/62926\/revisions"}],"predecessor-version":[{"id":63239,"href":"https:\/\/skan.com\/en\/wp-json\/wp\/v2\/expertise\/62926\/revisions\/63239"}],"wp:attachment":[{"href":"https:\/\/skan.com\/en\/wp-json\/wp\/v2\/media?parent=62926"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}