{"id":61919,"date":"2026-11-17T09:11:08","date_gmt":"2026-11-17T08:11:08","guid":{"rendered":"https:\/\/skan.com\/?post_type=expertise&#038;p=61919"},"modified":"2026-11-16T23:02:26","modified_gmt":"2026-11-16T22:02:26","slug":"aseptic-material-transfer","status":"publish","type":"expertise","link":"https:\/\/skan.com\/en\/expertise\/pharma\/aseptic-material-transfer","title":{"rendered":"Aseptic material transfer"},"content":{"rendered":"\r\n        \r\n        \r\n            <section  class=\"section-post-hero\">\r\n            <div class=\"container\">\r\n                <div class=\"section-post-hero-grid\">\r\n                    <div class=\"section-post-hero-media\">\r\n                        <div class=\"entry-media\">\r\n                            \r\n                                <figure class=\"\">\r\n                                                                            <img loading=\"lazy\" decoding=\"async\" width=\"2560\" height=\"1707\" src=\"https:\/\/skan.com\/wp-content\/uploads\/2026\/10\/mat-material-transfer-beta-container-application-scaled-e1791291148566.jpeg\" class=\"attachment-full size-full\" alt=\"\" \/>                                                                    <\/figure>\r\n                        <\/div>\r\n                    <\/div>\r\n                    <div class=\"section-post-hero-text\">\r\n                                                <div class=\"limiter\">\r\n                                                            <h1>Aseptic material transfer<\/h1>\r\n                                                                                        <p>Safely transferring materials into and out of the critical processing environment<\/p>\r\n                                                        <a class=\"link bottom anchor-link\" href=\"#nextSection\" role=\"button\">\r\n                                <span class=\"icon\"><span><span aria-hidden=\"true\"><\/span><\/span><\/span>\r\n                                <span class=\"text\">Learn more<\/span>\r\n                            <\/a>\r\n                        <\/div>\r\n                    <\/div>\r\n                <\/div>\r\n            <\/div>\r\n        <\/section>\r\n        <div aria-hidden=\"true\" id=\"nextSection\"><\/div>\r\n    \r\n    \r\n\n\n\t<section class=\"text-section two-cols\">\r\n\t\t<div  class=\"section-main twocolumns-section pt-default pb-default\">\r\n\t\t\t<div class=\"container\">\r\n\t\t\t\t                \t\t\t\t<div class=\"column-text full-width\">\r\n                                            <div class=\"text any-b0\">\r\n                            <h4>Tools, consumables and other auxiliary items must be introduced into the critical processing environment in a controlled manner and removed just as safely. Material transfer is therefore an essential part of the overall aseptic concept and can affect the safety of the entire production process.<\/h4>\n                        <\/div>\r\n                    \r\n                                            <div class=\"text any-b0\">\r\n                            <p>EU GMP Annex 1 permits only approved materials that have been assessed during transfer validation to pass through airlocks and pass-through hatches (4.12). For items sterilized in sealed packaging, the use of RTP technology should also be considered (8.47).<\/p>\n<p>The appropriate transfer solution depends, among other things, on material quantity, transfer frequency, the sterility status of the material and the desired process interface. Systems differ mainly with regard to where decontamination takes place and how the material reaches the process isolator.<\/p>\n                        <\/div>\r\n                    \t\t\t\t<\/div>\r\n\t\t\t<\/div>\r\n\t\t<\/div>\r\n\t<\/section>\r\n\n\n    <section id=\"Applications\" class=\"section-image-text pt-default pb-default reverse default\">\r\n        <div class=\"container\">\r\n            <div class=\"entry-grid\">\r\n                                    <div class=\"text\">\r\n                        <div class=\"text-inner\">\r\n                                                            <h5>Material transfer overview<\/h5>\r\n                                                                                        <h2>Typical applications<\/h2>\r\n                                                                                                                    <ul class=\"feature-list list-reset\">\r\n                                                                                                                                                                <li>\r\n                                                <div class=\"feature-item\">\r\n                                                                                                                                                                <div class=\"any-b0\">\r\n                                                            <h4>Components and consumables<\/h4>\n<p>For materials that are needed in the process, such as filling needles or Petri dishes \u2013 but also stoppers and caps that are supplied batch-wise rather than continuously.<\/p>\n                                                        <\/div>\r\n                                                                                                    <\/div>\r\n                                            <\/li>\r\n                                                                                                                                                                                                        <li>\r\n                                                <div class=\"feature-item\">\r\n                                                                                                                                                                <div class=\"any-b0\">\r\n                                                            <h4>Process equipment and tools<\/h4>\n<p>For tools, equipment and larger or frequently required items, e.g. for operation, format changes or maintenance.<\/p>\n                                                        <\/div>\r\n                                                                                                    <\/div>\r\n                                            <\/li>\r\n                                                                                                                                                                                                        <li>\r\n                                                <div class=\"feature-item\">\r\n                                                                                                                                                                <div class=\"any-b0\">\r\n                                                            <h4>Materials with special transfer requirements<\/h4>\n<p>For powders or materials that require closed transfer due to their nature, packaging (e.g. bags), or other requirements.<\/p>\n                                                        <\/div>\r\n                                                                                                    <\/div>\r\n                                            <\/li>\r\n                                                                                                                                                                                                        <li>\r\n                                                <div class=\"feature-item\">\r\n                                                                                                                                                                <div class=\"any-b0\">\r\n                                                            <h4>Waste and contaminated materials<\/h4>\n<p>For removing materials without compromising the barrier.<\/p>\n                                                        <\/div>\r\n                                                                                                    <\/div>\r\n                                            <\/li>\r\n                                                                                                            <\/ul>\r\n                                                                                        <a class=\"link\" href=\"https:\/\/skan.com\/en\/expertise\/pharma\/downloads\/aseptic-transfer-systems-for-isolator-and-rabs\" target=\"_self\" role=\"button\">\r\n                                    <span aria-hidden=\"true\"><\/span>\r\n                                    <span>Whitepaper: &quot;Transfer Systems for Isolator and RABS&quot;<\/span>\r\n                                <\/a>\r\n                                                    <\/div>\r\n                    <\/div>\r\n                                                    <div class=\"image\">\r\n                        <figure class=\"\">\r\n                                                            <img loading=\"lazy\" decoding=\"async\" width=\"2560\" height=\"2348\" src=\"https:\/\/skan.com\/wp-content\/uploads\/2026\/10\/FIG1___ATA-LK-Graphic-2025-scaled-e1791277320592.jpg\" class=\"attachment-full size-full\" alt=\"\" \/>                                                    <\/figure>\r\n                    <\/div>\r\n                            <\/div>\r\n        <\/div>\r\n    <\/section>\r\n\n\n    <section id=\"Systemcomparison\" class=\"section-download-accordions pt-default pb-default\">\r\n        <div class=\"container\">\r\n            <div class=\"entry-grid\">\r\n                <div class=\"any-b0\">\r\n                                            <h2>Comparison of the most common material transfer systems<\/h2>\r\n                                    <\/div>\r\n                                    <div>\r\n                                                    <ul class=\"site-accordion accordion list-reset\">\r\n                                                                                                                                                <li>\r\n                                            <button class=\"opener\" type=\"button\">\r\n                                                <span>Material transfer isolator<\/span>\r\n                                                <span class=\"icon\" aria-hidden=\"true\"><\/span>\r\n                                            <\/button>\r\n                                                                                            <div class=\"slide any-b0 has-custom-list\">\r\n                                                    <p><strong>Transfer principle:<\/strong> Material is decontaminated with H\u2082O\u2082 in a separate isolator chamber in the immediate vicinity of the filling line. After the cycle, it is handed over to the process isolator via a closed transfer system such as an RTP.<\/p>\n<p><strong>Potential advantages:<\/strong><\/p>\n<ul>\n<li>Suitable for large quantities and recurring material supply<\/li>\n<li>Controlled decontamination before handover to the aseptic process<\/li>\n<li>Allows materials to be prepared outside the process isolator<\/li>\n<\/ul>\n<p><strong>Considerations:<\/strong><\/p>\n<ul>\n<li>Additional process step between material supply and process isolator<\/li>\n<li>Decontamination cycle time must be integrated into the material flow<\/li>\n<li>Suitable interface required for the subsequent handover<\/li>\n<\/ul>\n                                                <\/div>\r\n                                                                                    <\/li>\r\n                                                                                                                                                                                    <li>\r\n                                            <button class=\"opener\" type=\"button\">\r\n                                                <span>Material airlock<\/span>\r\n                                                <span class=\"icon\" aria-hidden=\"true\"><\/span>\r\n                                            <\/button>\r\n                                                                                            <div class=\"slide any-b0 has-custom-list\">\r\n                                                    <p><strong>Transfer principle:<\/strong> Material is placed in an airlock chamber with two electrically interlocked doors. There it undergoes validated, automated surface decontamination, usually with hydrogen peroxide, under unidirectional once-through airflow without recirculation. The material is then transferred into the higher-classified area.<\/p>\n<p><strong>Potential advantages:<\/strong><\/p>\n<ul>\n<li>Flexible material transfer between areas of different cleanroom grades<\/li>\n<li>Short decontamination cycle including aeration &#8211; considerably shorter than for the main isolator chamber<\/li>\n<li>Various sizes, up to floor-level solutions for transfer trolleys<\/li>\n<\/ul>\n<p><strong>Considerations:<\/strong><\/p>\n<ul>\n<li>Airlock concept and cycle must be matched to material and process<\/li>\n<li>Material compatibility must be ensured<\/li>\n<li>Integration into the room and pressure concept, and space requirements<\/li>\n<\/ul>\n                                                <\/div>\r\n                                                                                    <\/li>\r\n                                                                                                                                                                                    <li>\r\n                                            <button class=\"opener\" type=\"button\">\r\n                                                <span>Rapid Transfer Port (RTP) system <\/span>\r\n                                                <span class=\"icon\" aria-hidden=\"true\"><\/span>\r\n                                            <\/button>\r\n                                                                                            <div class=\"slide any-b0 has-custom-list\">\r\n                                                    <p><strong>Transfer principle:<\/strong> A pre-sterilized, typically autoclaved beta container is docked from the outside to the isolator\u2019s alpha port. Only once securely locked can both doors be opened together and the material transferred directly into the isolator.<\/p>\n<p><strong>Potential advantages:<\/strong><\/p>\n<ul>\n<li>Direct, closed interface to the isolator<\/li>\n<li>No separate decontamination cycle if the material is supplied sterile<\/li>\n<li>Suitable for smaller quantities and frequent transfers<\/li>\n<\/ul>\n<p><strong>Considerations:<\/strong><\/p>\n<ul>\n<li>The narrow sealing area between alpha and beta door (\u201cring of concern\u201d) must be addressed in handling and risk assessment<\/li>\n<li>Container and contents must be supplied sterile<\/li>\n<li>Container capacity limits the quantity of material<\/li>\n<\/ul>\n                                                <\/div>\r\n                                                                                    <\/li>\r\n                                                                                                                                                                                    <li>\r\n                                            <button class=\"opener\" type=\"button\">\r\n                                                <span>Bag transfer systems<\/span>\r\n                                                <span class=\"icon\" aria-hidden=\"true\"><\/span>\r\n                                            <\/button>\r\n                                                                                            <div class=\"slide any-b0 has-custom-list\">\r\n                                                    <p><strong>Transfer principle: <\/strong>Materials are supplied in a pre-sterilized, usually gamma-irradiated transfer bag with a beta flange. The bag docks to the isolator\u2019s alpha port in the same way as an RTP container.<\/p>\n<p><strong>Potential advantages:<\/strong><\/p>\n<ul>\n<li>Closed transfer without a dedicated decontamination cycle<\/li>\n<li>Single-use solution \u2013 no cleaning or autoclaving of the container<\/li>\n<li>Suitable for powders, stoppers or caps<\/li>\n<\/ul>\n<p><strong>Considerations:<\/strong><\/p>\n<ul>\n<li>Sterilization method must be compatible with bag and contents, and validated<\/li>\n<li>Consumable costs and waste handling<\/li>\n<\/ul>\n                                                <\/div>\r\n                                                                                    <\/li>\r\n                                                                                                                                                                                    <li>\r\n                                            <button class=\"opener\" type=\"button\">\r\n                                                <span>Liner transfer systems<\/span>\r\n                                                <span class=\"icon\" aria-hidden=\"true\"><\/span>\r\n                                            <\/button>\r\n                                                                                            <div class=\"slide any-b0 has-custom-list\">\r\n                                                    <p><strong>Transfer principle:<\/strong> Material is collected in a liner and removed from the isolator via a closed interface.<\/p>\n<p><strong>Potential advantages:<\/strong><\/p>\n<ul>\n<li>Closed transfer out without opening the isolator barrier<\/li>\n<li>Particularly suitable for waste and contaminated materials<\/li>\n<li>Supports controlled separation of the process and surrounding areas<\/li>\n<\/ul>\n<p><strong>Considerations:<\/strong><\/p>\n<ul>\n<li>Liner and interface must be matched to material, quantity and transfer out<\/li>\n<li>Contaminated material entails additional containment and safe-handling requirements<\/li>\n<\/ul>\n                                                <\/div>\r\n                                                                                    <\/li>\r\n                                                                                                <\/ul>\r\n                                            <\/div>\r\n                            <\/div>\r\n        <\/div>\r\n    <\/section>\r\n\n\n\t<section class=\"text-section two-cols\">\r\n\t\t<div id=\"Outlook\" class=\"section-main twocolumns-section pt-default pb-default\">\r\n\t\t\t<div class=\"container\">\r\n\t\t\t\t\t\t\t\t\t<strong class=\"subtitle h5 full-width\">Outlook<\/strong>\r\n\t\t\t\t                \t\t\t\t\t<h1 class=\"h2 full-width\">Closed, flexible and increasingly automated transfers<\/h1>\r\n\t\t\t\t\t\t\t\t<div class=\"column-text full-width\">\r\n                                            <div class=\"text any-b0\">\r\n                            <p>Aseptic material transfer is increasingly moving toward closed and more integrated processes. Solutions that demonstrably control material flows, reduce manual interventions, and integrate seamlessly into the Contamination Control Strategy are gaining importance.<\/p>\n<p>Single-use technologies are also playing a growing role \u2013 especially for smaller batches, frequent product changeovers, and flexible production concepts. They can reduce cleaning and changeover effort but are not the optimal solution for every application. Material integrity and compatibility, handling, and the number of manual connections must also be taken into account.<\/p>\n                        <\/div>\r\n                    \r\n                                            <div class=\"text any-b0\">\r\n                            <p><strong>At the same time, transfer systems are evolving toward automation and process integration. The key question will therefore be less about an individual transfer system and more about a transfer concept that treats material, process, barrier technology, and production requirements as one overall system.<\/strong><\/p>\n                        <\/div>\r\n                    \t\t\t\t<\/div>\r\n\t\t\t<\/div>\r\n\t\t<\/div>\r\n\t<\/section>\r\n\n\n    <section id=\"Takeaways\" class=\"section-feature-grid pt-default pb-default\">\r\n        <div class=\"container\">\r\n                            <header class=\"entry-header any-b0\">\r\n                                            <h5>Summary<\/h5>\r\n                                                                <h2>Key takeaways<\/h2>\r\n                                    <\/header>\r\n                                        <ul class=\"feature-grid-list list-reset\">\r\n                                                                                                <li>\r\n                                <div class=\"feature-grid-item any-b0\">\r\n                                    <figure class=\"icon style-svg\" aria-hidden=\"true\">\r\n                                                                                    <svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"24\" height=\"24\" viewBox=\"0 0 24 24\" fill=\"none\"><rect x=\"0.5\" y=\"0.5\" width=\"23\" height=\"23\" rx=\"11.5\" fill=\"#E2ECF0\" stroke=\"#C5D9E1\"\/><path d=\"M7 11.7308L10.5 15.5L17 8.5\" stroke=\"#004682\" stroke-width=\"1.5\" stroke-linecap=\"square\"\/><\/svg>\r\n                                                                            <\/figure>\r\n                                                                            <h3>Material transfer is not a one-way street.<\/h3>\r\n                                                                                                                <p>Materials must not only be introduced safely into the critical processing environment but also removed under equally controlled conditions.<\/p>\r\n                                                                    <\/div>\r\n                            <\/li>\r\n                                                                                                                        <li>\r\n                                <div class=\"feature-grid-item any-b0\">\r\n                                    <figure class=\"icon style-svg\" aria-hidden=\"true\">\r\n                                                                                    <svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"24\" height=\"24\" viewBox=\"0 0 24 24\" fill=\"none\"><rect x=\"0.5\" y=\"0.5\" width=\"23\" height=\"23\" rx=\"11.5\" fill=\"#E2ECF0\" stroke=\"#C5D9E1\"\/><path d=\"M7 11.7308L10.5 15.5L17 8.5\" stroke=\"#004682\" stroke-width=\"1.5\" stroke-linecap=\"square\"\/><\/svg>\r\n                                                                            <\/figure>\r\n                                                                            <h3>Type and quantity determine the transfer system.<\/h3>\r\n                                                                                                                <p>The choice depends largely on which material is transferred, in what quantity, and for which process.<\/p>\r\n                                                                    <\/div>\r\n                            <\/li>\r\n                                                                                                                        <li>\r\n                                <div class=\"feature-grid-item any-b0\">\r\n                                    <figure class=\"icon style-svg\" aria-hidden=\"true\">\r\n                                                                                    <svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"24\" height=\"24\" viewBox=\"0 0 24 24\" fill=\"none\"><rect x=\"0.5\" y=\"0.5\" width=\"23\" height=\"23\" rx=\"11.5\" fill=\"#E2ECF0\" stroke=\"#C5D9E1\"\/><path d=\"M7 11.7308L10.5 15.5L17 8.5\" stroke=\"#004682\" stroke-width=\"1.5\" stroke-linecap=\"square\"\/><\/svg>\r\n                                                                            <\/figure>\r\n                                                                            <h3>Material transfers are typically batch-wise.<\/h3>\r\n                                                                                                                <p>Unlike continuous packaging transfers, material is transferred in or out on demand, i.e., in individual transfer cycles.<\/p>\r\n                                                                    <\/div>\r\n                            <\/li>\r\n                                                                                                                        <li>\r\n                                <div class=\"feature-grid-item any-b0\">\r\n                                    <figure class=\"icon style-svg\" aria-hidden=\"true\">\r\n                                                                                    <svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"24\" height=\"24\" viewBox=\"0 0 24 24\" fill=\"none\"><rect x=\"0.5\" y=\"0.5\" width=\"23\" height=\"23\" rx=\"11.5\" fill=\"#E2ECF0\" stroke=\"#C5D9E1\"\/><path d=\"M7 11.7308L10.5 15.5L17 8.5\" stroke=\"#004682\" stroke-width=\"1.5\" stroke-linecap=\"square\"\/><\/svg>\r\n                                                                            <\/figure>\r\n                                                                            <h3>Decontamination must match the transferred items.<\/h3>\r\n                                                                                                                <p>Where surface decontamination is part of the transfer, method and process parameters must be adapted to the material and validated.<\/p>\r\n                                                                    <\/div>\r\n                            <\/li>\r\n                                                                                                                        <li>\r\n                                <div class=\"feature-grid-item any-b0\">\r\n                                    <figure class=\"icon style-svg\" aria-hidden=\"true\">\r\n                                                                                    <svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"24\" height=\"24\" viewBox=\"0 0 24 24\" fill=\"none\"><rect x=\"0.5\" y=\"0.5\" width=\"23\" height=\"23\" rx=\"11.5\" fill=\"#E2ECF0\" stroke=\"#C5D9E1\"\/><path d=\"M7 11.7308L10.5 15.5L17 8.5\" stroke=\"#004682\" stroke-width=\"1.5\" stroke-linecap=\"square\"\/><\/svg>\r\n                                                                            <\/figure>\r\n                                                                            <h3>The interface is part of the process.<\/h3>\r\n                                                                                                                <p>Transfer system and barrier technology must be aligned so that material can be safely transferred into the critical processing environment.<\/p>\r\n                                                                    <\/div>\r\n                            <\/li>\r\n                                                                                                                        <li>\r\n                                <div class=\"feature-grid-item any-b0\">\r\n                                    <figure class=\"icon style-svg\" aria-hidden=\"true\">\r\n                                                                                    <svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"24\" height=\"24\" viewBox=\"0 0 24 24\" fill=\"none\"><rect x=\"0.5\" y=\"0.5\" width=\"23\" height=\"23\" rx=\"11.5\" fill=\"#E2ECF0\" stroke=\"#C5D9E1\"\/><path d=\"M7 11.7308L10.5 15.5L17 8.5\" stroke=\"#004682\" stroke-width=\"1.5\" stroke-linecap=\"square\"\/><\/svg>\r\n                                                                            <\/figure>\r\n                                                                            <h3>Approved materials only, validated routes only.<\/h3>\r\n                                                                                                                <p>Annex 1 requires a list of approved materials that have been assessed as part of transfer validation.<\/p>\r\n                                                                    <\/div>\r\n                            <\/li>\r\n                                                            <\/ul>\r\n                    <\/div>\r\n    <\/section>\r\n\r\n\n\n    <section id=\"Whitepapers\" class=\"section-teaser-slider pt-default pb-default\">\n        <div class=\"container\">\n                            <header class=\"entry-header any-b0\">\n                                            <h5>Expert insights<\/h5>\n                                                                <h2>Explore different transfer systems<\/h2>\n                                    <\/header>\n                                        <div class=\"teaser-slider swiper\">\n                    <button class=\"swiper-button-prev\" type=\"button\">\n                        <span class=\"accessibility\">Previous slide<\/span>\n                        <svg aria-hidden=\"true\" width=\"22\" height=\"18\" viewBox=\"0 0 22 18\" fill=\"none\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"m9 17.003-8-8 8-8M1 9.003h21\" stroke=\"#004682\"\/><\/svg>\n                    <\/button>\n                    <ul class=\"swiper-wrapper list-reset\">\n                                                                                                               <li class=\"swiper-slide\">\n                                    <article class=\"image-teaser-card\">\n    <a class=\"inner\" href=\"https:\/\/skan.com\/en\/expertise\/pharma\/downloads\/ebeam-tunnel-annex-1-compliant-rtu-transfer-system\">\n                    <figure>\n                <img loading=\"lazy\" decoding=\"async\" width=\"1280\" height=\"1829\" src=\"https:\/\/skan.com\/wp-content\/uploads\/2026\/10\/skan-ebeam-transfer-system-rtu-e1791293220629.jpeg\" class=\"attachment-full size-full\" alt=\"\" \/>            <\/figure>\n                            <div>\n                                    <h5>Whitepaper<\/h5>\n                                                    <h2>&#8220;Electron-Beam Tunnel: An Annex-1-Compliant RTU Transfer System&#8221;<\/h2>\n                                                    <span class=\"link link-white\" role=\"button\">\n                        <span aria-hidden=\"true\"><\/span>\n                        <span>Get the whitepaper (Tech4Pharma, 2025)<\/span>\n                    <\/span>\n                            <\/div>\n            <\/a>\n<\/article>                                <\/li>\n                                                                                                                                            <li class=\"swiper-slide\">\n                                    <article class=\"image-teaser-card\">\n    <a class=\"inner\" href=\"https:\/\/skan.com\/en\/expertise\/pharma\/downloads\/ebeam-surface-sterilization-rtu\">\n                    <figure>\n                <img loading=\"lazy\" decoding=\"async\" width=\"1404\" height=\"1560\" src=\"https:\/\/skan.com\/wp-content\/uploads\/2026\/03\/skan-ebeam-emitters-usp2_resize-1.jpg\" class=\"attachment-full size-full\" alt=\"Two SKAN e-beam emitters with circular white covers integrated into a complex stainless steel industrial assembly with cables and sensors.\" srcset=\"https:\/\/skan.com\/wp-content\/uploads\/2026\/03\/skan-ebeam-emitters-usp2_resize-1.jpg 1404w, https:\/\/skan.com\/wp-content\/uploads\/2026\/03\/skan-ebeam-emitters-usp2_resize-1-270x300.jpg 270w, https:\/\/skan.com\/wp-content\/uploads\/2026\/03\/skan-ebeam-emitters-usp2_resize-1-922x1024.jpg 922w, https:\/\/skan.com\/wp-content\/uploads\/2026\/03\/skan-ebeam-emitters-usp2_resize-1-768x853.jpg 768w, https:\/\/skan.com\/wp-content\/uploads\/2026\/03\/skan-ebeam-emitters-usp2_resize-1-1382x1536.jpg 1382w, https:\/\/skan.com\/wp-content\/uploads\/2026\/03\/skan-ebeam-emitters-usp2_resize-1-357x397.jpg 357w\" sizes=\"auto, (max-width: 1404px) 100vw, 1404px\" \/>            <\/figure>\n                            <div>\n                                    <h5>Whitepaper<\/h5>\n                                                    <h2>&#8220;Ebeam Surface Sterilization of Ready-to-use Units&#8221;<\/h2>\n                                                    <span class=\"link link-white\" role=\"button\">\n                        <span aria-hidden=\"true\"><\/span>\n                        <span>Get the whitepaper (pharmind, 2024)<\/span>\n                    <\/span>\n                            <\/div>\n            <\/a>\n<\/article>                                <\/li>\n                                                                                                                                            <li class=\"swiper-slide\">\n                                    <article class=\"image-teaser-card\">\n    <a class=\"inner\" href=\"https:\/\/skan.com\/en\/expertise\/pharma\/downloads\/material-transfer-isolators-fast-safe-transfers\">\n                    <figure>\n                <img loading=\"lazy\" decoding=\"async\" width=\"1404\" height=\"1560\" src=\"https:\/\/skan.com\/wp-content\/uploads\/2026\/10\/mat-material-transfer-isolator-flexibility-usp3_resize-e1791293107882.jpg\" class=\"attachment-full size-full\" alt=\"\" \/>            <\/figure>\n                            <div>\n                                    <h5>Whitepaper<\/h5>\n                                                    <h2>&#8220;Material Transfer Isolators: Key Components for Fast and Safe transfers in Aseptic Filling Lines&#8221;<\/h2>\n                                                    <span class=\"link link-white\" role=\"button\">\n                        <span aria-hidden=\"true\"><\/span>\n                        <span>Get the whitepaper (Tech4Pharma, 2026)<\/span>\n                    <\/span>\n                            <\/div>\n            <\/a>\n<\/article>                                <\/li>\n                                                                                                                                            <li class=\"swiper-slide\">\n                                    <article class=\"image-teaser-card\">\n    <a class=\"inner\" href=\"https:\/\/skan.com\/en\/expertise\/pharma\/downloads\/material-airlocks-safe-and-controlled-room-to-room-transfers\">\n                    <figure>\n                <img loading=\"lazy\" decoding=\"async\" width=\"1280\" height=\"1195\" src=\"https:\/\/skan.com\/wp-content\/uploads\/2026\/10\/cellana-sara-airlock-e1791293167467.jpeg\" class=\"attachment-full size-full\" alt=\"\" \/>            <\/figure>\n                            <div>\n                                    <h5>Whitepaper<\/h5>\n                                                    <h2>&#8220;Material Airlocks: Safe and Controlled Room-to-Room Transfers&#8221;<\/h2>\n                                                    <span class=\"link link-white\" role=\"button\">\n                        <span aria-hidden=\"true\"><\/span>\n                        <span>Get the whitepaper (cleanroom &amp; processes, 2026)<\/span>\n                    <\/span>\n                            <\/div>\n            <\/a>\n<\/article>                                <\/li>\n                                                                                                                                            <li class=\"swiper-slide\">\n                                    <article class=\"image-teaser-card\">\n    <a class=\"inner\" href=\"https:\/\/skan.com\/en\/expertise\/pharma\/aseptic-transfer-systems\">\n                    <figure>\n                <img loading=\"lazy\" decoding=\"async\" width=\"1404\" height=\"1560\" src=\"https:\/\/skan.com\/wp-content\/uploads\/2026\/10\/rabs-operator-safety-regulatory-approved_resize-e1791293050684.jpg\" class=\"attachment-full size-full\" alt=\"\" \/>            <\/figure>\n                            <div>\n                                    <h5>Overview<\/h5>\n                                                    <h2>Overview of different transfer systems and their applications<\/h2>\n                                                    <span class=\"link link-white\" role=\"button\">\n                        <span aria-hidden=\"true\"><\/span>\n                        <span>Go to overview<\/span>\n                    <\/span>\n                            <\/div>\n            <\/a>\n<\/article>                                <\/li>\n                                                                        <\/ul>\n                    <button class=\"swiper-button-next\" type=\"button\">\n                        <span class=\"accessibility\">Next slide<\/span>\n                        <svg aria-hidden=\"true\" width=\"22\" height=\"18\" viewBox=\"0 0 22 18\" fill=\"none\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"m13 17.003 8-8-8-8M21 9.003H0\" stroke=\"#004682\"\/><\/svg>\n                    <\/button>\n                    <nav class=\"swiper-pagination\"><\/nav>\n                <\/div>\n                    <\/div>\n    <\/section>\n\n\n\n\n\n    <section  class=\"section-contact-teaser pt-default pb-default\">\r\n        <div class=\"contact-teaser-block viewport-section\">\r\n            <div class=\"container\">\r\n                                    <div class=\"limiter any-b0\">\r\n                                                    <h2>Looking for the right transfer system?<\/h2>\r\n                                                <p>Contact our team of experts to jointly evaluate the right solution for your material flows, process requirements, and barrier technology.<\/p>\n                    <\/div>\r\n                                                    <ul class=\"contact-teaser-list list-reset\">\r\n                                                                                <li>\r\n                                <a href=\"https:\/\/skan.com\/en\/contact?pid=61919\" target=\"_self\">\r\n                                                                        \r\n                                                                            <span class=\"text\">Contact<\/span>\r\n                                    \r\n                                    <span aria-hidden=\"true\"><\/span>\r\n                                <\/a>\r\n                            <\/li>\r\n                                                                                <li>\r\n                                <a href=\"https:\/\/skan.com\/en\/products\/pharma\/transfer-systems\/material-transfer-isolator?pid=61919\" target=\"_self\">\r\n                                                                        \r\n                                                                            <span class=\"text\">Learn more about the material transfer isolator<\/span>\r\n                                    \r\n                                    <span aria-hidden=\"true\"><\/span>\r\n                                <\/a>\r\n                            <\/li>\r\n                                            <\/ul>\r\n                            <\/div>\r\n        <\/div>\r\n    <\/section>\r\n","protected":false},"featured_media":0,"template":"","meta":{"_acf_changed":false,"inline_featured_image":false,"footnotes":""},"class_list":["post-61919","expertise","type-expertise","status-publish","hentry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Aseptic material transfer - SKAN<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/skan.com\/en\/expertise\/pharma\/aseptic-material-transfer\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Aseptic material transfer - SKAN\" \/>\n<meta property=\"og:url\" content=\"https:\/\/skan.com\/en\/expertise\/pharma\/aseptic-material-transfer\" \/>\n<meta property=\"og:site_name\" content=\"SKAN\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/skan.com\\\/en\\\/expertise\\\/pharma\\\/aseptic-material-transfer\",\"url\":\"https:\\\/\\\/skan.com\\\/en\\\/expertise\\\/pharma\\\/aseptic-material-transfer\",\"name\":\"Aseptic material transfer - SKAN\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/skan.com\\\/en\\\/#website\"},\"datePublished\":\"2026-11-17T08:11:08+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/skan.com\\\/en\\\/expertise\\\/pharma\\\/aseptic-material-transfer#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/skan.com\\\/en\\\/expertise\\\/pharma\\\/aseptic-material-transfer\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/skan.com\\\/en\\\/expertise\\\/pharma\\\/aseptic-material-transfer#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Startseite\",\"item\":\"https:\\\/\\\/skan.com\\\/en\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Aseptic material transfer\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/skan.com\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/skan.com\\\/en\\\/\",\"name\":\"SKAN\",\"description\":\"Ihr Partner f\u00fcr Forschungslaboratorien\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/skan.com\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Aseptic material transfer - SKAN","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/skan.com\/en\/expertise\/pharma\/aseptic-material-transfer","og_locale":"en_US","og_type":"article","og_title":"Aseptic material transfer - SKAN","og_url":"https:\/\/skan.com\/en\/expertise\/pharma\/aseptic-material-transfer","og_site_name":"SKAN","twitter_card":"summary_large_image","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/skan.com\/en\/expertise\/pharma\/aseptic-material-transfer","url":"https:\/\/skan.com\/en\/expertise\/pharma\/aseptic-material-transfer","name":"Aseptic material transfer - SKAN","isPartOf":{"@id":"https:\/\/skan.com\/en\/#website"},"datePublished":"2026-11-17T08:11:08+00:00","breadcrumb":{"@id":"https:\/\/skan.com\/en\/expertise\/pharma\/aseptic-material-transfer#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/skan.com\/en\/expertise\/pharma\/aseptic-material-transfer"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/skan.com\/en\/expertise\/pharma\/aseptic-material-transfer#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Startseite","item":"https:\/\/skan.com\/en"},{"@type":"ListItem","position":2,"name":"Aseptic material transfer"}]},{"@type":"WebSite","@id":"https:\/\/skan.com\/en\/#website","url":"https:\/\/skan.com\/en\/","name":"SKAN","description":"Ihr Partner f\u00fcr Forschungslaboratorien","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/skan.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"}]}},"permalink_manager":null,"_links":{"self":[{"href":"https:\/\/skan.com\/en\/wp-json\/wp\/v2\/expertise\/61919","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/skan.com\/en\/wp-json\/wp\/v2\/expertise"}],"about":[{"href":"https:\/\/skan.com\/en\/wp-json\/wp\/v2\/types\/expertise"}],"version-history":[{"count":19,"href":"https:\/\/skan.com\/en\/wp-json\/wp\/v2\/expertise\/61919\/revisions"}],"predecessor-version":[{"id":63121,"href":"https:\/\/skan.com\/en\/wp-json\/wp\/v2\/expertise\/61919\/revisions\/63121"}],"wp:attachment":[{"href":"https:\/\/skan.com\/en\/wp-json\/wp\/v2\/media?parent=61919"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}