{"id":61813,"date":"2026-11-09T13:24:35","date_gmt":"2026-11-09T12:24:35","guid":{"rendered":"https:\/\/skan.com\/?post_type=expertise&#038;p=61813"},"modified":"2026-11-12T14:51:06","modified_gmt":"2026-11-12T13:51:06","slug":"reinraumklassen","status":"publish","type":"expertise","link":"https:\/\/skan.com\/de\/expertise\/labor-reinraum\/reinraumklassen","title":{"rendered":"Reinraumklassen"},"content":{"rendered":"\r\n\r\n\n\n\r\n        \r\n        \r\n            <section  class=\"section-post-hero\">\r\n            <div class=\"container\">\r\n                <div class=\"section-post-hero-grid\">\r\n                    <div class=\"section-post-hero-media\">\r\n                        <div class=\"entry-media\">\r\n                            \r\n                                <figure class=\"\">\r\n                                                                            <img loading=\"lazy\" decoding=\"async\" width=\"702\" height=\"780\" src=\"https:\/\/skan.com\/wp-content\/uploads\/2026\/02\/ppe-tyvek-in-cleanroom.png\" class=\"attachment-full size-full\" alt=\"a man wearing PPE from Tyvek in a cleanroom\" srcset=\"https:\/\/skan.com\/wp-content\/uploads\/2026\/02\/ppe-tyvek-in-cleanroom.png 702w, https:\/\/skan.com\/wp-content\/uploads\/2026\/02\/ppe-tyvek-in-cleanroom-270x300.png 270w, https:\/\/skan.com\/wp-content\/uploads\/2026\/02\/ppe-tyvek-in-cleanroom-357x397.png 357w\" sizes=\"auto, (max-width: 702px) 100vw, 702px\" \/>                                                                    <\/figure>\r\n                        <\/div>\r\n                    <\/div>\r\n                    <div class=\"section-post-hero-text\">\r\n                                                <div class=\"limiter\">\r\n                                                            <h1>Reinraumklassen: Klassifizierung und Anforderungen im \u00dcberblick<\/h1>\r\n                                                                                        <p>Wie sauber ist ein Reinraum?<\/p>\r\n                                                        <a class=\"link bottom anchor-link\" href=\"#nextSection\" role=\"button\">\r\n                                <span class=\"icon\"><span><span aria-hidden=\"true\"><\/span><\/span><\/span>\r\n                                <span class=\"text\">Mehr erfahren<\/span>\r\n                            <\/a>\r\n                        <\/div>\r\n                    <\/div>\r\n                <\/div>\r\n            <\/div>\r\n        <\/section>\r\n        <div aria-hidden=\"true\" id=\"nextSection\"><\/div>\r\n    \r\n    \r\n\n\n        <section  class=\"section-headers pt-default pb-default two-column\">\n        <div class=\"container\">\n                                                    <div class=\"headers-grid two-column\">\n                                            <div class=\"text any-b0\">\n                            <h3 data-pm-slice=\"1 1 []\">Um die Luftreinheit messbar und vergleichbar zu machen, werden Reinr\u00e4ume anhand festgelegter Kriterien klassifiziert. Die Klassifizierung basiert auf der Anzahl luftgetragener Partikel bestimmter Gr\u00f6ssen pro Kubikmeter Luft.<\/h3>\n                        <\/div>\n                                                                <div class=\"text any-b0\">\n                            <p data-pm-slice=\"1 1 []\">Reinr\u00e4ume sind kontrollierte Umgebungen, in denen die Konzentration luftgetragener Partikel auf definierte Grenzwerte begrenzt wird. Sie kommen \u00fcberall dort zum Einsatz, wo Verunreinigungen die Qualit\u00e4t, Sicherheit oder Funktion eines Produkts oder Prozesses beeintr\u00e4chtigen k\u00f6nnen \u2013 beispielsweise in der pharmazeutischen Industrie, der Medizintechnik, der Mikroelektronik und der Forschung.<\/p>\n                        <\/div>\n                                    <\/div>\n                    <\/div>\n    <\/section>\n\n\n\n    <section  class=\"section-image-text pt-default pb-default reverse default\">\r\n        <div class=\"container\">\r\n            <div class=\"entry-grid\">\r\n                                    <div class=\"text\">\r\n                        <div class=\"text-inner\">\r\n                                                            <h5>ISO vs. GMP<\/h5>\r\n                                                                                        <h2>Reinraumklassen nach DIN EN ISO 14644-1<\/h2>\r\n                                                        <p data-pm-slice=\"1 1 []\">Die internationale Norm ISO 14644-1 unterteilt Reinr\u00e4ume in neun Klassen, von ISO 1 bis ISO 9. ISO 1 bezeichnet die h\u00f6chste Reinheitsstufe, w\u00e4hrend ISO 9 die niedrigste Reinheitsstufe innerhalb dieser Klassifizierung darstellt.<\/p>\n<p>Die Einteilung erfolgt anhand der maximal zul\u00e4ssigen Konzentration luftgetragener Partikel unterschiedlicher Gr\u00f6ssen. Die Partikelkonzentration wird mit geeigneten Partikelmessger\u00e4ten ermittelt und dient als Grundlage f\u00fcr die Klassifizierung der Luftreinheit.<\/p>\n<p>ISO-Klassen werden in verschiedenen Branchen eingesetzt, beispielsweise in der Mikroelektronik, der optischen Industrie, der Medizintechnik und der Forschung.<\/p>\n                                                                                <\/div>\r\n                    <\/div>\r\n                                                    <div class=\"image\">\r\n                        <figure class=\"\">\r\n                                                            <img loading=\"lazy\" decoding=\"async\" width=\"702\" height=\"780\" src=\"https:\/\/skan.com\/wp-content\/uploads\/2026\/02\/people-waearing-ppe-in-cleanroom.png\" class=\"attachment-full size-full\" alt=\"People wearing ppe in cleanroom\" srcset=\"https:\/\/skan.com\/wp-content\/uploads\/2026\/02\/people-waearing-ppe-in-cleanroom.png 702w, https:\/\/skan.com\/wp-content\/uploads\/2026\/02\/people-waearing-ppe-in-cleanroom-270x300.png 270w, https:\/\/skan.com\/wp-content\/uploads\/2026\/02\/people-waearing-ppe-in-cleanroom-357x397.png 357w\" sizes=\"auto, (max-width: 702px) 100vw, 702px\" \/>                                                    <\/figure>\r\n                    <\/div>\r\n                            <\/div>\r\n        <\/div>\r\n    <\/section>\r\n\n\n    <section  class=\"section-image-text pt-default pb-default default\">\r\n        <div class=\"container\">\r\n            <div class=\"entry-grid\">\r\n                                    <div class=\"text\">\r\n                        <div class=\"text-inner\">\r\n                                                            <h5>ISO vs. GMP<\/h5>\r\n                                                                                        <h2>Reinraumklassen nach EU-GMP-Leitfaden Annex 1<\/h2>\r\n                                                        <p data-pm-slice=\"1 1 []\">In der pharmazeutischen Herstellung steriler Arzneimittel gelten zus\u00e4tzlich die Anforderungen des EU-GMP-Leitfadens Annex 1. Dieser unterscheidet die Reinraumklassen A, B, C und D. Klasse A stellt dabei die h\u00f6chste Reinheitsstufe dar.<\/p>\n<p>Im Gegensatz zur reinen Partikelklassifizierung ber\u00fccksichtigt das GMP-Regelwerk auch mikrobiologische Kontaminationen und weitere Anforderungen an die kontrollierte Herstellung steriler Arzneimittel. Die Anforderungen richten sich nach dem jeweiligen Prozess und dem damit verbundenen Kontaminationsrisiko.<\/p>\n<p>Die GMP-Klassen werden unter anderem bei der Herstellung steriler Arzneimittel eingesetzt. Die konkrete Zuordnung und die erforderlichen Grenzwerte m\u00fcssen anhand der geltenden GMP-Vorgaben und der jeweiligen Anwendung bestimmt werden.<\/p>\n                                                                                <\/div>\r\n                    <\/div>\r\n                                                    <div class=\"image\">\r\n                        <figure class=\"\">\r\n                                                            <img loading=\"lazy\" decoding=\"async\" width=\"702\" height=\"780\" src=\"https:\/\/skan.com\/wp-content\/uploads\/2026\/02\/people-waearing-ppe-in-cleanroom.png\" class=\"attachment-full size-full\" alt=\"People wearing ppe in cleanroom\" srcset=\"https:\/\/skan.com\/wp-content\/uploads\/2026\/02\/people-waearing-ppe-in-cleanroom.png 702w, https:\/\/skan.com\/wp-content\/uploads\/2026\/02\/people-waearing-ppe-in-cleanroom-270x300.png 270w, https:\/\/skan.com\/wp-content\/uploads\/2026\/02\/people-waearing-ppe-in-cleanroom-357x397.png 357w\" sizes=\"auto, (max-width: 702px) 100vw, 702px\" \/>                                                    <\/figure>\r\n                    <\/div>\r\n                            <\/div>\r\n        <\/div>\r\n    <\/section>\r\n\n\n\t<section class=\"text-section one-col\">\r\n\t\t<div  class=\"section-main twocolumns-section pt-default pb-default\">\r\n\t\t\t<div class=\"container\">\r\n\t\t\t\t                \t\t\t\t\t<h1 class=\"h2 full-width\">Reinraumklassen nach ISO 14644-1: Zul\u00e4ssige Partikelkonzentrationen<\/h1>\r\n\t\t\t\t\t\t\t\t<div class=\"column-text full-width\">\r\n                                            <div class=\"text any-b0\">\r\n                            <p data-pm-slice=\"1 1 []\">Die folgende Tabelle zeigt die maximal zul\u00e4ssige Anzahl luftgetragener Partikel pro Kubikmeter Luft f\u00fcr die verschiedenen ISO-Reinraumklassen.<\/p>\n<p>Die Tabelle zeigt, wie stark sich die zul\u00e4ssige Partikelkonzentration zwischen den Klassen unterscheidet. W\u00e4hrend f\u00fcr ISO 5 beispielsweise maximal 3&#8217;520 Partikel mit einer Gr\u00f6sse von mindestens 0,5 \u00b5m pro Kubikmeter zul\u00e4ssig sind, liegt der entsprechende Grenzwert f\u00fcr ISO 8 bei 3&#8217;520&#8217;000 Partikeln.<\/p>\n<p><em>Angaben in Partikeln pro Kubikmeter Luft. <\/em><\/p>\n                        <\/div>\r\n                    \r\n                    \t\t\t\t<\/div>\r\n\t\t\t<\/div>\r\n\t\t<\/div>\r\n\t<\/section>\r\n\n\n<div class=\"g-container\"><div class=\"inner\">\n<figure class=\"wp-block-table is-style-stripes\"><table class=\"has-fixed-layout\" style=\"border-style:none;border-width:0px\"><tbody><tr><td><strong>Gr\u00f6sse<\/strong><\/td><td>0,1 \u00b5m<\/td><td>0,2 \u00b5m<\/td><td>0,3 \u00b5m<\/td><td>0,5 \u00b5m<\/td><td>1 \u00b5m<\/td><td>5 \u00b5m<\/td><\/tr><tr><td><strong>Klasse<\/strong><\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><\/tr><tr><td>ISO 1<\/td><td>10<\/td><td>2<\/td><td><\/td><td><\/td><td><\/td><td><\/td><\/tr><tr><td>ISO 2<\/td><td>100<\/td><td>24<\/td><td>10<\/td><td>4<\/td><td><\/td><td><\/td><\/tr><tr><td>ISO 3<\/td><td>1000<\/td><td>237<\/td><td>102<\/td><td>35<\/td><td>8<\/td><td><\/td><\/tr><tr><td>ISO 4<\/td><td>10&#8217;000<\/td><td>2370<\/td><td>1020<\/td><td>352<\/td><td>83<\/td><td><\/td><\/tr><tr><td>ISO 5<\/td><td>100&#8217;000<\/td><td>23&#8217;700<\/td><td>10&#8217;200<\/td><td>3520<\/td><td>832<\/td><td>29<\/td><\/tr><tr><td>ISO 6<\/td><td>1&#8217;000&#8217;000<\/td><td>237&#8217;000<\/td><td>102&#8217;000<\/td><td>35&#8217;200<\/td><td>8320<\/td><td>293<\/td><\/tr><tr><td>ISO 7<\/td><td><\/td><td><\/td><td><\/td><td>352&#8217;000<\/td><td>83&#8217;200<\/td><td>2930<\/td><\/tr><tr><td>ISO 8<\/td><td><\/td><td><\/td><td><\/td><td>3&#8217;520&#8217;000<\/td><td>832&#8217;000<\/td><td>29&#8217;300<\/td><\/tr><tr><td>ISO 9<\/td><td><\/td><td><\/td><td><\/td><td>35&#8217;200&#8217;000<\/td><td>8&#8217;320&#8217;000<\/td><td>293&#8217;000<\/td><\/tr><\/tbody><\/table><\/figure>\n<\/div><\/div>\n\n    <section  class=\"section-hotspot-element pt-default pb-default\">\r\n        <div class=\"container\">\r\n                            <header class=\"entry-header any-b0\">\r\n                                            <h5>Gr\u00f6ssenvergleich<\/h5>\r\n                                                        <\/header>\r\n                                                <div class=\"hotspot-block-wrap\">\r\n                <div class=\"hotspot-scrollable\">\r\n                    <figure class=\"hotspot-block\">\r\n                        <img decoding=\"async\" src=\"https:\/\/skan.com\/wp-content\/uploads\/2026\/10\/Groessenvergleich-ISO.jpg\" alt=\"Hotspot-Bild\">\r\n                                            <\/figure>\r\n                <\/div>\r\n            <\/div>\r\n                    <\/div>\r\n    <\/section>\r\n\n\n\t<section class=\"text-section one-col\">\r\n\t\t<div  class=\"section-main twocolumns-section pt-default pb-default\">\r\n\t\t\t<div class=\"container\">\r\n\t\t\t\t                \t\t\t\t\t<h1 class=\"h2 full-width\">GMP-Reinraumklassen: Grenzwerte im Ruhezustand und im Betrieb<\/h1>\r\n\t\t\t\t\t\t\t\t<div class=\"column-text full-width\">\r\n                                            <div class=\"text any-b0\">\r\n                            <p data-pm-slice=\"1 1 []\">Im pharmazeutischen Umfeld werden die GMP-Klassen A bis D anhand spezifischer Anforderungen an die Reinraumumgebung unterschieden. Die folgende \u00dcbersicht zeigt die in der zugrunde gelegten Tabelle aufgef\u00fchrten Grenzwerte f\u00fcr luftgetragene Partikel.<\/p>\n<p data-pm-slice=\"1 1 []\">Die Unterscheidung zwischen Ruhezustand und Betriebszustand ist wichtig, weil Mitarbeitende, Arbeitsabl\u00e4ufe und eingesetzte Materialien die Partikelkonzentration beeinflussen k\u00f6nnen. Insbesondere bei der Herstellung steriler Arzneimittel m\u00fcssen die Anforderungen an die Reinraumumgebung auf den jeweiligen Prozess abgestimmt werden.<\/p>\n<p>&nbsp;<\/p>\n                        <\/div>\r\n                    \r\n                    \t\t\t\t<\/div>\r\n\t\t\t<\/div>\r\n\t\t<\/div>\r\n\t<\/section>\r\n\n\n<div class=\"g-container\"><div class=\"inner\">\n<figure class=\"wp-block-table is-style-stripes\"><table class=\"has-fixed-layout\" style=\"border-style:none;border-width:0px\"><tbody><tr><td><strong>Gr\u00f6sse<\/strong><\/td><td>Ruhezustand \u2265 0,5 \u00b5m<\/td><td>Ruhezustand \u2265 5 \u00b5m<\/td><td>Betriebszustand \u2265 0,5 \u00b5m<\/td><td>Betriebszustand \u2265 5 \u00b5m<\/td><\/tr><tr><td><strong>Klasse<\/strong><\/td><td><\/td><td><\/td><td><\/td><td><\/td><\/tr><tr><td>A<\/td><td>3&#8217;520<\/td><td>20<\/td><td>3&#8217;520<\/td><td>20<\/td><\/tr><tr><td>B<\/td><td>3&#8217;520<\/td><td>29<\/td><td>352&#8217;000<\/td><td>2&#8217;900<\/td><\/tr><tr><td>C<\/td><td>352&#8217;000<\/td><td>2&#8217;900<\/td><td>3&#8217;520&#8217;000<\/td><td>29&#8217;000<\/td><\/tr><tr><td>D<\/td><td>3&#8217;520&#8217;000<\/td><td>29&#8217;000<\/td><td>Nicht definiert<\/td><td>Nicht definiert<\/td><\/tr><\/tbody><\/table><\/figure>\n<\/div><\/div>\n\n\t<section class=\"text-section one-col\">\r\n\t\t<div  class=\"section-main twocolumns-section pt-default pb-default\">\r\n\t\t\t<div class=\"container\">\r\n\t\t\t\t                \t\t\t\t\t<h1 class=\"h2 full-width\">Warum ist die richtige Reinraumklasse entscheidend?<\/h1>\r\n\t\t\t\t\t\t\t\t<div class=\"column-text full-width\">\r\n                                            <div class=\"text any-b0\">\r\n                            <p data-pm-slice=\"1 1 []\">Die erforderliche Reinraumklasse richtet sich nach den Anforderungen des Produkts und des Prozesses. Eine m\u00f6glichst hohe Reinheitsklasse ist nicht automatisch f\u00fcr jede Anwendung notwendig. Entscheidend ist, dass die Umgebung die erforderliche Luftreinheit gew\u00e4hrleistet und die relevanten Kontaminationsrisiken kontrolliert werden.<\/p>\n<p data-pm-slice=\"1 1 []\">Die Reinraumklassifizierung ist damit ein wichtiger Bestandteil der Planung, Qualifizierung und \u00dcberwachung kontrollierter Umgebungen.<\/p>\n                        <\/div>\r\n                    \r\n                    \t\t\t\t<\/div>\r\n\t\t\t<\/div>\r\n\t\t<\/div>\r\n\t<\/section>\r\n\n\n    <section id=\"kontakt\" class=\"section-contact-teaser pt-default pb-default\">\r\n        <div class=\"contact-teaser-block viewport-section\">\r\n            <div class=\"container\">\r\n                                    <div class=\"limiter any-b0\">\r\n                                                    <h2>Sie m\u00f6chten mehr \u00fcber unsere L\u00f6sungen f\u00fcr kontrollierte Umgebungen erfahren?<\/h2>\r\n                                                <p data-pm-slice=\"1 1 []\">Kontaktieren Sie uns.<\/p>\n                    <\/div>\r\n                                                    <ul class=\"contact-teaser-list list-reset\">\r\n                                                                                <li>\r\n                                <a href=\"https:\/\/skan.com\/de\/kontakt?pid=61813\" target=\"_self\">\r\n                                                                        \r\n                                                                            <span class=\"text\">Kontakt<\/span>\r\n                                    \r\n                                    <span aria-hidden=\"true\"><\/span>\r\n                                <\/a>\r\n                            <\/li>\r\n                                            <\/ul>\r\n                            <\/div>\r\n        <\/div>\r\n    <\/section>\r\n","protected":false},"featured_media":0,"template":"","meta":{"_acf_changed":false,"inline_featured_image":false,"footnotes":""},"class_list":["post-61813","expertise","type-expertise","status-publish","hentry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Reinraumklassen - SKAN<\/title>\n<meta name=\"description\" content=\"Reinr\u00e4ume sind kontrollierte Umgebungen, in denen die Konzentration luftgetragener Partikel auf definierte Grenzwerte begrenzt wird.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/skan.com\/de\/expertise\/labor-reinraum\/reinraumklassen\" \/>\n<meta property=\"og:locale\" content=\"de_DE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Reinraumklassen - SKAN\" \/>\n<meta property=\"og:description\" content=\"Reinr\u00e4ume sind kontrollierte Umgebungen, in denen die Konzentration luftgetragener Partikel auf definierte Grenzwerte begrenzt wird.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/skan.com\/de\/expertise\/labor-reinraum\/reinraumklassen\" \/>\n<meta property=\"og:site_name\" content=\"SKAN\" \/>\n<meta property=\"article:modified_time\" content=\"2026-11-12T13:51:06+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Gesch\u00e4tzte Lesezeit\" \/>\n\t<meta name=\"twitter:data1\" content=\"1\u00a0Minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/skan.com\\\/de\\\/expertise\\\/labor-reinraum\\\/reinraumklassen\",\"url\":\"https:\\\/\\\/skan.com\\\/de\\\/expertise\\\/labor-reinraum\\\/reinraumklassen\",\"name\":\"Reinraumklassen - SKAN\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/skan.com\\\/de\\\/#website\"},\"datePublished\":\"2026-11-09T12:24:35+00:00\",\"dateModified\":\"2026-11-12T13:51:06+00:00\",\"description\":\"Reinr\u00e4ume sind kontrollierte Umgebungen, in denen die Konzentration luftgetragener Partikel auf definierte Grenzwerte begrenzt wird.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/skan.com\\\/de\\\/expertise\\\/labor-reinraum\\\/reinraumklassen#breadcrumb\"},\"inLanguage\":\"de\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/skan.com\\\/de\\\/expertise\\\/labor-reinraum\\\/reinraumklassen\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/skan.com\\\/de\\\/expertise\\\/labor-reinraum\\\/reinraumklassen#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Startseite\",\"item\":\"https:\\\/\\\/skan.com\\\/de\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Reinraumklassen\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/skan.com\\\/de\\\/#website\",\"url\":\"https:\\\/\\\/skan.com\\\/de\\\/\",\"name\":\"SKAN\",\"description\":\"Ihr Partner f\u00fcr Forschungslaboratorien\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/skan.com\\\/de\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"de\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Reinraumklassen - SKAN","description":"Reinr\u00e4ume sind kontrollierte Umgebungen, in denen die Konzentration luftgetragener Partikel auf definierte Grenzwerte begrenzt wird.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/skan.com\/de\/expertise\/labor-reinraum\/reinraumklassen","og_locale":"de_DE","og_type":"article","og_title":"Reinraumklassen - SKAN","og_description":"Reinr\u00e4ume sind kontrollierte Umgebungen, in denen die Konzentration luftgetragener Partikel auf definierte Grenzwerte begrenzt wird.","og_url":"https:\/\/skan.com\/de\/expertise\/labor-reinraum\/reinraumklassen","og_site_name":"SKAN","article_modified_time":"2026-11-12T13:51:06+00:00","twitter_card":"summary_large_image","twitter_misc":{"Gesch\u00e4tzte Lesezeit":"1\u00a0Minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/skan.com\/de\/expertise\/labor-reinraum\/reinraumklassen","url":"https:\/\/skan.com\/de\/expertise\/labor-reinraum\/reinraumklassen","name":"Reinraumklassen - SKAN","isPartOf":{"@id":"https:\/\/skan.com\/de\/#website"},"datePublished":"2026-11-09T12:24:35+00:00","dateModified":"2026-11-12T13:51:06+00:00","description":"Reinr\u00e4ume sind kontrollierte Umgebungen, in denen die Konzentration luftgetragener Partikel auf definierte Grenzwerte begrenzt wird.","breadcrumb":{"@id":"https:\/\/skan.com\/de\/expertise\/labor-reinraum\/reinraumklassen#breadcrumb"},"inLanguage":"de","potentialAction":[{"@type":"ReadAction","target":["https:\/\/skan.com\/de\/expertise\/labor-reinraum\/reinraumklassen"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/skan.com\/de\/expertise\/labor-reinraum\/reinraumklassen#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Startseite","item":"https:\/\/skan.com\/de"},{"@type":"ListItem","position":2,"name":"Reinraumklassen"}]},{"@type":"WebSite","@id":"https:\/\/skan.com\/de\/#website","url":"https:\/\/skan.com\/de\/","name":"SKAN","description":"Ihr Partner f\u00fcr Forschungslaboratorien","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/skan.com\/de\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"de"}]}},"permalink_manager":null,"_links":{"self":[{"href":"https:\/\/skan.com\/de\/wp-json\/wp\/v2\/expertise\/61813","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/skan.com\/de\/wp-json\/wp\/v2\/expertise"}],"about":[{"href":"https:\/\/skan.com\/de\/wp-json\/wp\/v2\/types\/expertise"}],"version-history":[{"count":5,"href":"https:\/\/skan.com\/de\/wp-json\/wp\/v2\/expertise\/61813\/revisions"}],"predecessor-version":[{"id":62380,"href":"https:\/\/skan.com\/de\/wp-json\/wp\/v2\/expertise\/61813\/revisions\/62380"}],"wp:attachment":[{"href":"https:\/\/skan.com\/de\/wp-json\/wp\/v2\/media?parent=61813"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}