{"id":60071,"date":"2026-11-16T15:57:02","date_gmt":"2026-11-16T14:57:02","guid":{"rendered":"https:\/\/skan.com\/?post_type=expertise&#038;p=60071"},"modified":"2026-11-17T18:04:24","modified_gmt":"2026-11-17T17:04:24","slug":"hepa-filter-in-der-aseptischen-produktion-skan","status":"publish","type":"expertise","link":"https:\/\/skan.com\/de\/expertise\/pharma\/filter","title":{"rendered":"Filter"},"content":{"rendered":"\r\n\r\n\n\n\r\n        \r\n        \r\n            <section  class=\"section-post-hero\">\r\n            <div class=\"container\">\r\n                <div class=\"section-post-hero-grid\">\r\n                    <div class=\"section-post-hero-media\">\r\n                        <div class=\"entry-media\">\r\n                            \r\n                                <figure class=\"\">\r\n                                                                            <img loading=\"lazy\" decoding=\"async\" width=\"2347\" height=\"1792\" src=\"https:\/\/skan.com\/wp-content\/uploads\/2026\/11\/safe-change-filter-in-isolator.jpeg\" class=\"attachment-full size-full\" alt=\"\" srcset=\"https:\/\/skan.com\/wp-content\/uploads\/2026\/11\/safe-change-filter-in-isolator.jpeg 2347w, https:\/\/skan.com\/wp-content\/uploads\/2026\/11\/safe-change-filter-in-isolator-300x229.jpeg 300w, https:\/\/skan.com\/wp-content\/uploads\/2026\/11\/safe-change-filter-in-isolator-1024x782.jpeg 1024w, https:\/\/skan.com\/wp-content\/uploads\/2026\/11\/safe-change-filter-in-isolator-768x586.jpeg 768w, https:\/\/skan.com\/wp-content\/uploads\/2026\/11\/safe-change-filter-in-isolator-1536x1173.jpeg 1536w, https:\/\/skan.com\/wp-content\/uploads\/2026\/11\/safe-change-filter-in-isolator-2048x1564.jpeg 2048w, https:\/\/skan.com\/wp-content\/uploads\/2026\/11\/safe-change-filter-in-isolator-357x273.jpeg 357w\" sizes=\"auto, (max-width: 2347px) 100vw, 2347px\" \/>                                                                    <\/figure>\r\n                        <\/div>\r\n                    <\/div>\r\n                    <div class=\"section-post-hero-text\">\r\n                                                <div class=\"limiter\">\r\n                                                            <h1>Filter in der aseptischen Produktion<\/h1>\r\n                                                                                        <p>Warum HEPA-Filter \u00fcber Produktqualit\u00e4t entscheiden<\/p>\r\n                                                        <a class=\"link bottom anchor-link\" href=\"#nextSection\" role=\"button\">\r\n                                <span class=\"icon\"><span><span aria-hidden=\"true\"><\/span><\/span><\/span>\r\n                                <span class=\"text\">Mehr erfahren<\/span>\r\n                            <\/a>\r\n                        <\/div>\r\n                    <\/div>\r\n                <\/div>\r\n            <\/div>\r\n        <\/section>\r\n        <div aria-hidden=\"true\" id=\"nextSection\"><\/div>\r\n    \r\n    \r\n\n\n        <section  class=\"section-headers pt-default pb-default two-column\">\n        <div class=\"container\">\n                                                    <div class=\"headers-grid two-column\">\n                                            <div class=\"text any-b0\">\n                            <h4>In aseptischen Prozessen ist kontrollierte Luftf\u00fchrung kein unterst\u00fctzendes Element \u2013 sie ist ein kritischer Bestandteil der Sterilit\u00e4tssicherung.<\/h4>\n                        <\/div>\n                                                                <div class=\"text any-b0\">\n                            <p>Hocheffizienzfilter stellen sicher, dass Partikel und Mikroorganismen zuverl\u00e4ssig aus der Luft entfernt werden, bevor sie den Prozessbereich erreichen.<br \/>\nGleichzeitig steigen die Anforderungen: neue Therapien, komplexere Prozesse und strengere regulatorische Erwartungen machen Filtertechnologie zu einem zentralen Hebel f\u00fcr Sicherheit, Effizienz und Validierbarkeit.<\/p>\n                        <\/div>\n                                    <\/div>\n                    <\/div>\n    <\/section>\n\n\n\n    <section  class=\"section-feature-grid pt-default pb-default\">\r\n        <div class=\"container\">\r\n                            <header class=\"entry-header any-b0\">\r\n                                            <h5>Warum Filtration anspruchsvoller wird<\/h5>\r\n                                                                <h2>Herausforderungen der Filtertechnologie<\/h2>\r\n                                    <\/header>\r\n                                        <ul class=\"feature-grid-list list-reset\">\r\n                                                                                                <li>\r\n                                <div class=\"feature-grid-item any-b0\">\r\n                                    <figure class=\"icon style-svg\" aria-hidden=\"true\">\r\n                                                                                    <img loading=\"lazy\" decoding=\"async\" width=\"24\" height=\"24\" src=\"https:\/\/skan.com\/wp-content\/uploads\/2026\/09\/Exclamationmark.png\" class=\"attachment-full size-full\" alt=\"\" \/>                                                                            <\/figure>\r\n                                                                            <h3>Zunehmende Komplexit\u00e4t der Produkte<\/h3>\r\n                                                                                                                <p>Neue Modalit\u00e4ten (z. B. virale Vektoren) stellen neue Anforderungen an Partikelkontrolle und Risikobewertung<\/p>\r\n                                                                    <\/div>\r\n                            <\/li>\r\n                                                                                                                        <li>\r\n                                <div class=\"feature-grid-item any-b0\">\r\n                                    <figure class=\"icon style-svg\" aria-hidden=\"true\">\r\n                                                                                    <img loading=\"lazy\" decoding=\"async\" width=\"24\" height=\"24\" src=\"https:\/\/skan.com\/wp-content\/uploads\/2026\/09\/Exclamationmark.png\" class=\"attachment-full size-full\" alt=\"\" \/>                                                                            <\/figure>\r\n                                                                            <h3>Unsichtbare Schwachstellen<\/h3>\r\n                                                                                                                <p>Leckagen in Filtermedien oder Dichtungen sind nicht sichtbar, haben aber direkten Einfluss auf die Produktqualit\u00e4t<\/p>\r\n                                                                    <\/div>\r\n                            <\/li>\r\n                                                                                                                        <li>\r\n                                <div class=\"feature-grid-item any-b0\">\r\n                                    <figure class=\"icon style-svg\" aria-hidden=\"true\">\r\n                                                                                    <img loading=\"lazy\" decoding=\"async\" width=\"24\" height=\"24\" src=\"https:\/\/skan.com\/wp-content\/uploads\/2026\/09\/Exclamationmark.png\" class=\"attachment-full size-full\" alt=\"\" \/>                                                                            <\/figure>\r\n                                                                            <h3>Validierungsaufwand<\/h3>\r\n                                                                                                                <p>Integrit\u00e4tspr\u00fcfungen sind technisch anspruchsvoll und m\u00fcssen reproduzierbar, dokumentiert und regulatorisch belastbar sein<\/p>\r\n                                                                    <\/div>\r\n                            <\/li>\r\n                                                            <\/ul>\r\n                    <\/div>\r\n    <\/section>\r\n\r\n\n\n    <section  class=\"section-image-text pt-default pb-default default\">\r\n        <div class=\"container\">\r\n            <div class=\"entry-grid\">\r\n                                    <div class=\"text\">\r\n                        <div class=\"text-inner\">\r\n                                                            <h5>Wie HEPA-Filter tats\u00e4chlich funktionieren<\/h5>\r\n                                                                                        <h2>Grundlagen der Filtertechnologie<\/h2>\r\n                                                        <p>HEPA-Filter bestehen aus fein strukturierten Glasfasern. Sie halten Partikel nicht nur wie ein Sieb zur\u00fcck, sondern scheiden sie \u00fcber mehrere physikalische Effekte ab: Sehr kleine Partikel werden vor allem durch Diffusion abgeschieden, mittlere durch den Sperreffekt und gr\u00f6ssere durch Tr\u00e4gheit und den Siebeffekt.<\/p>\n                                                                                <\/div>\r\n                    <\/div>\r\n                                                    <div class=\"image\">\r\n                        <figure class=\"\">\r\n                                                            <img loading=\"lazy\" decoding=\"async\" width=\"1472\" height=\"1344\" src=\"https:\/\/skan.com\/wp-content\/uploads\/2026\/09\/Abscheidemechanismen_HEPA_DE-2-e1794500044803.png\" class=\"attachment-full size-full\" alt=\"illustration of filter mechanisms in a hepa filter\" srcset=\"https:\/\/skan.com\/wp-content\/uploads\/2026\/09\/Abscheidemechanismen_HEPA_DE-2-e1794500044803.png 1472w, https:\/\/skan.com\/wp-content\/uploads\/2026\/09\/Abscheidemechanismen_HEPA_DE-2-e1794500044803-300x274.png 300w, https:\/\/skan.com\/wp-content\/uploads\/2026\/09\/Abscheidemechanismen_HEPA_DE-2-e1794500044803-1024x935.png 1024w, https:\/\/skan.com\/wp-content\/uploads\/2026\/09\/Abscheidemechanismen_HEPA_DE-2-e1794500044803-768x701.png 768w, https:\/\/skan.com\/wp-content\/uploads\/2026\/09\/Abscheidemechanismen_HEPA_DE-2-e1794500044803-357x326.png 357w\" sizes=\"auto, (max-width: 1472px) 100vw, 1472px\" \/>                                                    <\/figure>\r\n                    <\/div>\r\n                            <\/div>\r\n        <\/div>\r\n    <\/section>\r\n\n\n    <section  class=\"section-image-text pt-0 pb-default default\">\r\n        <div class=\"container\">\r\n            <div class=\"entry-grid\">\r\n                                    <div class=\"text\">\r\n                        <div class=\"text-inner\">\r\n                                                                                    <p>Am schwierigsten abzuscheiden sind nicht die kleinsten Partikel, sondern solche im Bereich von ca. 0.1\u20130.2 \u00b5m \u2013 die sogenannte MPPS (Most Penetrating Particle Size). Nach dieser Worst-Case-Gr\u00f6sse werden Filter klassifiziert. Bei allen anderen Partikelgr\u00f6ssen liegt die Abscheidung h\u00f6her. Partikel ab 5 \u00b5m werden vollst\u00e4ndig zur\u00fcckgehalten.<\/p>\n                                                                                <\/div>\r\n                    <\/div>\r\n                                                    <div class=\"image\">\r\n                        <figure class=\"\">\r\n                                                            <img loading=\"lazy\" decoding=\"async\" width=\"1404\" height=\"844\" src=\"https:\/\/skan.com\/wp-content\/uploads\/2026\/11\/abscheidegrad-partikelgroesse.jpg\" class=\"attachment-full size-full\" alt=\"\" srcset=\"https:\/\/skan.com\/wp-content\/uploads\/2026\/11\/abscheidegrad-partikelgroesse.jpg 1404w, https:\/\/skan.com\/wp-content\/uploads\/2026\/11\/abscheidegrad-partikelgroesse-300x180.jpg 300w, https:\/\/skan.com\/wp-content\/uploads\/2026\/11\/abscheidegrad-partikelgroesse-1024x616.jpg 1024w, https:\/\/skan.com\/wp-content\/uploads\/2026\/11\/abscheidegrad-partikelgroesse-768x462.jpg 768w, https:\/\/skan.com\/wp-content\/uploads\/2026\/11\/abscheidegrad-partikelgroesse-357x215.jpg 357w\" sizes=\"auto, (max-width: 1404px) 100vw, 1404px\" \/>                                                    <\/figure>\r\n                    <\/div>\r\n                            <\/div>\r\n        <\/div>\r\n    <\/section>\r\n\n\n    <section  class=\"section-image-text pt-default pb-default default\">\r\n        <div class=\"container\">\r\n            <div class=\"entry-grid\">\r\n                                    <div class=\"text\">\r\n                        <div class=\"text-inner\">\r\n                                                            <h5>Wie Sicherheit nachgewiesen wird<\/h5>\r\n                                                                                        <h2>Regulatorik &amp; Filterintegrit\u00e4t<\/h2>\r\n                                                        <p>Filter m\u00fcssen nicht nur funktionieren, sondern nachweisbar korrekt funktionieren. F\u00fcr den Einsatz in der aseptischen Produktion ist deshalb nicht allein die Leistungsf\u00e4higkeit eines Filters entscheidend, sondern auch deren dokumentierter Nachweis.<\/p>\n<p>Relevante Standards:<\/p>\n<p>ISO 14644-1 (Reinraumklassifikation)<br \/>\nISO 14644-3 (Pr\u00fcfmethoden)<br \/>\nISO 29463 \/ EN 1822 (Filterklassifikation und -pr\u00fcfung)<br \/>\nEU GMP Annex 1 (Anforderungen an aseptische Prozesse)<\/p>\n<p>Dabei sind zwei Pr\u00fcfebenen zu unterscheiden: Filterklasse und Leckfreiheit werden beim Hersteller auf dem Pr\u00fcfstand nachgewiesen. Im eingebauten Zustand geht es darum, ob dieser Zustand erhalten geblieben ist: Ist der Filter bei Transport oder Einbau unbesch\u00e4digt geblieben?<\/p>\n<p>F\u00fcr den Integrit\u00e4tsnachweis vor Ort stehen zwei Methoden zur Verf\u00fcgung: die Overall-Messung, die die Gesamtleistung des eingebauten Filters bewertet, und das Scanning, das lokale Leckagen im Filtermedium aufsp\u00fcrt. Ein Filter kann die Gesamtleistung erf\u00fcllen und dennoch lokale Leckagen aufweisen. Bei Terminalfiltern direkt \u00fcber dem Produkt kommt deshalb das Scanning zum Einsatz.<\/p>\n                                                                                <\/div>\r\n                    <\/div>\r\n                                                    <div class=\"image\">\r\n                        <figure class=\"\">\r\n                                                            <img loading=\"lazy\" decoding=\"async\" width=\"1070\" height=\"1160\" src=\"https:\/\/skan.com\/wp-content\/uploads\/2026\/09\/hepa-filter-closeup-e1791975102552.png\" class=\"attachment-full size-full\" alt=\"close up of a hepa filter\" srcset=\"https:\/\/skan.com\/wp-content\/uploads\/2026\/09\/hepa-filter-closeup-e1791975102552.png 1070w, https:\/\/skan.com\/wp-content\/uploads\/2026\/09\/hepa-filter-closeup-e1791975102552-277x300.png 277w, https:\/\/skan.com\/wp-content\/uploads\/2026\/09\/hepa-filter-closeup-e1791975102552-945x1024.png 945w, https:\/\/skan.com\/wp-content\/uploads\/2026\/09\/hepa-filter-closeup-e1791975102552-768x833.png 768w, https:\/\/skan.com\/wp-content\/uploads\/2026\/09\/hepa-filter-closeup-e1791975102552-357x387.png 357w\" sizes=\"auto, (max-width: 1070px) 100vw, 1070px\" \/>                                                    <\/figure>\r\n                    <\/div>\r\n                            <\/div>\r\n        <\/div>\r\n    <\/section>\r\n\n\n    <section  class=\"section-column-element pt-default pb-default\">\r\n        <div class=\"container\">\r\n                                        <ul class=\"column-element-list list-reset\">\r\n                                                                                                <li>\r\n                                <div class=\"column-element\">\r\n                                                                                                                <div class=\"body any-b0\">\r\n                                                                                            <h3>1. Pr\u00fcfprinzip<\/h3>\r\n                                                                                        <p>Die Integrit\u00e4tspr\u00fcfung vergleicht die Partikelkonzentration vor und nach dem Filter. Dazu wird ein definiertes Testaerosol (z. B. DEHS) vor dem Filter aufgegeben, und die Messung erfolgt typischerweise bei Partikeln \u2265 0.3 \u00b5m. Voraussetzung f\u00fcr valide Ergebnisse ist eine homogene Verteilung des Aerosols \u00fcber die gesamte Filterfl\u00e4che.<\/p>\n                                        <\/div>\r\n                                                                    <\/div>\r\n                            <\/li>\r\n                                                                                                                        <li>\r\n                                <div class=\"column-element\">\r\n                                                                                                                <div class=\"body any-b0\">\r\n                                                                                            <h3>2. Overall-Messung<\/h3>\r\n                                                                                        <p>Die Overall-Messung erfasst die Partikelkonzentration im gesamten Luftstrom nach dem Filter. Sie zeigt, ob der eingebaute Filter seine Gesamtabscheideleistung erbringt, lokalisiert aber keine einzelnen Leckagen.<\/p>\n                                        <\/div>\r\n                                                                    <\/div>\r\n                            <\/li>\r\n                                                                                                                        <li>\r\n                                <div class=\"column-element\">\r\n                                                                                                                <div class=\"body any-b0\">\r\n                                                                                            <h3>3. Scanning<\/h3>\r\n                                                                                        <p>Beim Scanning wird die Filterfl\u00e4che mit einer Messsonde abgefahren. So lassen sich lokale Leckagen im Filtermedium oder am Dichtsitz gezielt aufsp\u00fcren. Das ist bei Terminalfiltern kritisch, da sie die letzte Barriere vor dem Prozessbereich bilden.<\/p>\n                                        <\/div>\r\n                                                                    <\/div>\r\n                            <\/li>\r\n                                                            <\/ul>\r\n                    <\/div>\r\n    <\/section>\r\n\r\n\r\n\n\n    <section  class=\"section-image-text pt-default pb-default default\">\r\n        <div class=\"container\">\r\n            <div class=\"entry-grid\">\r\n                                    <div class=\"text\">\r\n                        <div class=\"text-inner\">\r\n                                                            <h5>Warum Filterleistung vom Systemdesign abh\u00e4ngt<\/h5>\r\n                                                                                        <h2>Design, Integration &amp; Filterkonzepte<\/h2>\r\n                                                        <p>Filtertechnologie funktioniert nicht isoliert, sondern als Teil eines Gesamtsystems. Wie gut ein Filter im Betrieb tats\u00e4chlich sch\u00fctzt, h\u00e4ngt wesentlich davon ab, wo und wie er eingebaut ist.<\/p>\n<p>Entscheidend ist zun\u00e4chst die Position im Luftstrom: Zuluftfilter versorgen das System mit gereinigter Luft, Terminalfilter bilden die letzte Barriere vor dem kritischen Bereich, und R\u00fcckluft- bzw. Abluftfilter verhindern Kreuzkontamination und sch\u00fctzen Personal und Umgebung. Ebenso pr\u00e4gend ist die Luftf\u00fchrung. Eine unidirektionale (laminare) Str\u00f6mung f\u00fchrt m\u00f6glichePartikel gezielt vom Prozess weg, w\u00e4hrend turbulente Str\u00f6mungen sie eher verwirbeln. In Isolatoren kommen zus\u00e4tzliche Rahmenbedingungen hinzu: begrenzter Platz, eingeschr\u00e4nkte Zug\u00e4nglichkeit und die Frage, wie sich ein Filter im eingebauten Zustand \u00fcberhaupt pr\u00fcfen l\u00e4sst.<\/p>\n<p>In aseptischen Anlagen sind zwei Bauformen besonders verbreitet. Beide erf\u00fcllen die Anforderungen an die Partikelabscheidung, unterscheiden sich aber in Integration, Testbarkeit, Wartung und Eignung f\u00fcr Containment-Anwendungen.<\/p>\n                                                                                <\/div>\r\n                    <\/div>\r\n                                                    <div class=\"image\">\r\n                        <figure class=\"\">\r\n                                                            <img loading=\"lazy\" decoding=\"async\" width=\"1348\" height=\"1160\" src=\"https:\/\/skan.com\/wp-content\/uploads\/2026\/09\/design-integration-hepa-filter-e1791975877907.png\" class=\"attachment-full size-full\" alt=\"safe change hepa filter installed in an isolator\" srcset=\"https:\/\/skan.com\/wp-content\/uploads\/2026\/09\/design-integration-hepa-filter-e1791975877907.png 1348w, https:\/\/skan.com\/wp-content\/uploads\/2026\/09\/design-integration-hepa-filter-e1791975877907-300x258.png 300w, https:\/\/skan.com\/wp-content\/uploads\/2026\/09\/design-integration-hepa-filter-e1791975877907-1024x881.png 1024w, https:\/\/skan.com\/wp-content\/uploads\/2026\/09\/design-integration-hepa-filter-e1791975877907-768x661.png 768w, https:\/\/skan.com\/wp-content\/uploads\/2026\/09\/design-integration-hepa-filter-e1791975877907-357x307.png 357w\" sizes=\"auto, (max-width: 1348px) 100vw, 1348px\" \/>                                                    <\/figure>\r\n                    <\/div>\r\n                            <\/div>\r\n        <\/div>\r\n    <\/section>\r\n\n\n    <section  class=\"section-column-element pt-default pb-default\">\r\n        <div class=\"container\">\r\n                            <header class=\"entry-header any-b0\">\r\n                                            <h5>Welche Bauform wof\u00fcr geeignet ist<\/h5>\r\n                                                                <h2>Typische Filterkonzepte in Isolatorsystemen<\/h2>\r\n                                    <\/header>\r\n                                        <ul class=\"column-element-list list-reset\">\r\n                                                                                                <li>\r\n                                <div class=\"column-element\">\r\n                                                                            <figure>\r\n                                            <img loading=\"lazy\" decoding=\"async\" width=\"1404\" height=\"1560\" src=\"https:\/\/skan.com\/wp-content\/uploads\/2026\/09\/hepa-filter-planar.png\" class=\"attachment-full size-full\" alt=\"Flat (planar) HEPA filter\" srcset=\"https:\/\/skan.com\/wp-content\/uploads\/2026\/09\/hepa-filter-planar.png 1404w, https:\/\/skan.com\/wp-content\/uploads\/2026\/09\/hepa-filter-planar-270x300.png 270w, https:\/\/skan.com\/wp-content\/uploads\/2026\/09\/hepa-filter-planar-922x1024.png 922w, https:\/\/skan.com\/wp-content\/uploads\/2026\/09\/hepa-filter-planar-768x853.png 768w, https:\/\/skan.com\/wp-content\/uploads\/2026\/09\/hepa-filter-planar-1382x1536.png 1382w, https:\/\/skan.com\/wp-content\/uploads\/2026\/09\/hepa-filter-planar-357x397.png 357w\" sizes=\"auto, (max-width: 1404px) 100vw, 1404px\" \/>                                        <\/figure>\r\n                                                                                                                <div class=\"body any-b0\">\r\n                                                                                            <h3>Flache (planare) HEPA-Filter<\/h3>\r\n                                                                                        <ul>\n<li>Klassische, rechteckige Filterelemente<\/li>\n<li>H\u00e4ufig als Terminalfilter direkt \u00fcber dem kritischen Bereich eingesetzt<\/li>\n<li>Erm\u00f6glichen eine gleichm\u00e4ssige, unidirektionale Luftstr\u00f6mung \u00fcber die gesamte Arbeitsfl\u00e4che<\/li>\n<li>Bei entsprechender Zug\u00e4nglichkeit direkt per Scanning auf Leckagen pr\u00fcfbar<\/li>\n<\/ul>\n<p>Diese Bauform kommt dort zum Einsatz, wo eine direkte, homogene Luftf\u00fchrung \u00fcber dem Prozess erforderlich ist.<\/p>\n                                        <\/div>\r\n                                                                    <\/div>\r\n                            <\/li>\r\n                                                                                                                        <li>\r\n                                <div class=\"column-element\">\r\n                                                                            <figure>\r\n                                            <img loading=\"lazy\" decoding=\"async\" width=\"1404\" height=\"1560\" src=\"https:\/\/skan.com\/wp-content\/uploads\/2026\/09\/Safe-change-filter-cartridge.png\" class=\"attachment-full size-full\" alt=\"Filter cartridge \/ safe-change filter\" srcset=\"https:\/\/skan.com\/wp-content\/uploads\/2026\/09\/Safe-change-filter-cartridge.png 1404w, https:\/\/skan.com\/wp-content\/uploads\/2026\/09\/Safe-change-filter-cartridge-270x300.png 270w, https:\/\/skan.com\/wp-content\/uploads\/2026\/09\/Safe-change-filter-cartridge-922x1024.png 922w, https:\/\/skan.com\/wp-content\/uploads\/2026\/09\/Safe-change-filter-cartridge-768x853.png 768w, https:\/\/skan.com\/wp-content\/uploads\/2026\/09\/Safe-change-filter-cartridge-1382x1536.png 1382w, https:\/\/skan.com\/wp-content\/uploads\/2026\/09\/Safe-change-filter-cartridge-357x397.png 357w\" sizes=\"auto, (max-width: 1404px) 100vw, 1404px\" \/>                                        <\/figure>\r\n                                                                                                                <div class=\"body any-b0\">\r\n                                                                                            <h3>Filterpatronen \/ Safe-change-Filter<\/h3>\r\n                                                                                        <ul>\n<li>In sich geschlossene Filtereinheiten<\/li>\n<li><span style=\"letter-spacing: 0.0222222em\">Einsatz vor allem in R\u00fcckluft- und Containment-Bereichen<\/span><\/li>\n<li>Ausgelegt f\u00fcr einen Austausch ohne Freisetzung von Kontamination<\/li>\n<li>Eigene Testkonzepte, z. B. vorgelagerte Tests oder die Dichtheitspr\u00fcfung des Einbaus<\/li>\n<\/ul>\n<p>In Anwendungen mit erh\u00f6htem Risiko, etwa bei toxischen Substanzen, ist dieser kontrollierte Filterwechsel ein zentraler Bestandteil des Gesamtkonzepts.<\/p>\n                                        <\/div>\r\n                                                                    <\/div>\r\n                            <\/li>\r\n                                                            <\/ul>\r\n                    <\/div>\r\n    <\/section>\r\n\r\n\r\n\n\n    <section  class=\"section-image-text pt-default pb-default default\">\r\n        <div class=\"container\">\r\n            <div class=\"entry-grid\">\r\n                                    <div class=\"text\">\r\n                        <div class=\"text-inner\">\r\n                                                            <h5>Filter im Betrieb verstehen<\/h5>\r\n                                                                                        <h2>Wartung, Lebenszyklus &amp; untersch\u00e4tzte Faktoren<\/h2>\r\n                                                        <p>Filter sind kein statisches Bauteil. Integrit\u00e4tstests werden regelm\u00e4ssig wiederholt, typischerweise alle 6\u201312 Monate, und ein Austausch erfolgt je nach Materialalterung, Dichtungen und Prozessbedingungen oft nach 3 Jahren. In toxischen Anwendungen lassen sich belastete Filter nicht gefahrlos vor Ort pr\u00fcfen. Hier sind Safe-change-Konzepte zentral.<\/p>\n<p><strong>Was oft untersch\u00e4tzt wird<\/strong><\/p>\n<ul>\n<li>Mechanische Belastung: Glassplitter und andere Partikel k\u00f6nnen Filtermedien besch\u00e4digen.<\/li>\n<li>Dichtheit und Leckfreiheit nach Wartung: Erst eine erneute Integrit\u00e4tspr\u00fcfung best\u00e4tigt, dass Filter und Dichtsitz wieder einwandfrei sind.<\/li>\n<li>Zug\u00e4nglichkeit f\u00fcr Tests: Sie sollte bereits bei der Wahl des Filterdesigns ber\u00fccksichtigt werden.<\/li>\n<\/ul>\n                                                                                <\/div>\r\n                    <\/div>\r\n                                                    <div class=\"image\">\r\n                        <figure class=\"\">\r\n                                                            <img loading=\"lazy\" decoding=\"async\" width=\"1412\" height=\"1162\" src=\"https:\/\/skan.com\/wp-content\/uploads\/2026\/10\/safe-change-filter-in-isolator-e1792047711497.jpeg\" class=\"attachment-full size-full\" alt=\"\" srcset=\"https:\/\/skan.com\/wp-content\/uploads\/2026\/10\/safe-change-filter-in-isolator-e1792047711497.jpeg 1412w, https:\/\/skan.com\/wp-content\/uploads\/2026\/10\/safe-change-filter-in-isolator-e1792047711497-300x247.jpeg 300w, https:\/\/skan.com\/wp-content\/uploads\/2026\/10\/safe-change-filter-in-isolator-e1792047711497-1024x843.jpeg 1024w, https:\/\/skan.com\/wp-content\/uploads\/2026\/10\/safe-change-filter-in-isolator-e1792047711497-768x632.jpeg 768w, https:\/\/skan.com\/wp-content\/uploads\/2026\/10\/safe-change-filter-in-isolator-e1792047711497-357x294.jpeg 357w\" sizes=\"auto, (max-width: 1412px) 100vw, 1412px\" \/>                                                    <\/figure>\r\n                    <\/div>\r\n                            <\/div>\r\n        <\/div>\r\n    <\/section>\r\n\n\n    <section  class=\"section-image-text pt-default pb-default default\">\r\n        <div class=\"container\">\r\n            <div class=\"entry-grid\">\r\n                                    <div class=\"text\">\r\n                        <div class=\"text-inner\">\r\n                                                            <h5>Wohin sich Filtertechnologie entwickelt<\/h5>\r\n                                                                                        <h2>Ausblick<\/h2>\r\n                                                        <p>Die Physik der Filtration ist etabliert. Weiterentwicklungen zielen heute auf das Gesamtsystem: automatisierte Scansysteme f\u00fcr eine verbesserte Testbarkeit, sicherere und effizientere Wartungskonzepte sowie Simulation und CFD, um Luftstr\u00f6mung und Partikelverhalten bereits in der Planung vorherzusagen.<\/p>\n<p>Ein fundierter Umgang mit Filtertechnologie \u2013 von der Integration \u00fcber die Validierung bis zum Betrieb \u2013 ist damit ein zentraler Baustein f\u00fcr robuste aseptische Prozesse.<\/p>\n                                                                                <\/div>\r\n                    <\/div>\r\n                                                    <div class=\"image\">\r\n                        <figure class=\"\">\r\n                                                            <img loading=\"lazy\" decoding=\"async\" width=\"1407\" height=\"1164\" src=\"https:\/\/skan.com\/wp-content\/uploads\/2026\/10\/safe-change-filter-in-chamber-1-e1792054626199.jpeg\" class=\"attachment-full size-full\" alt=\"\" srcset=\"https:\/\/skan.com\/wp-content\/uploads\/2026\/10\/safe-change-filter-in-chamber-1-e1792054626199.jpeg 1407w, https:\/\/skan.com\/wp-content\/uploads\/2026\/10\/safe-change-filter-in-chamber-1-e1792054626199-300x248.jpeg 300w, https:\/\/skan.com\/wp-content\/uploads\/2026\/10\/safe-change-filter-in-chamber-1-e1792054626199-1024x847.jpeg 1024w, https:\/\/skan.com\/wp-content\/uploads\/2026\/10\/safe-change-filter-in-chamber-1-e1792054626199-768x635.jpeg 768w, https:\/\/skan.com\/wp-content\/uploads\/2026\/10\/safe-change-filter-in-chamber-1-e1792054626199-357x295.jpeg 357w\" sizes=\"auto, (max-width: 1407px) 100vw, 1407px\" \/>                                                    <\/figure>\r\n                    <\/div>\r\n                            <\/div>\r\n        <\/div>\r\n    <\/section>\r\n\n\n    <section id=\"kontakt\" class=\"section-contact-teaser pt-default pb-default\">\r\n        <div class=\"contact-teaser-block viewport-section\">\r\n            <div class=\"container\">\r\n                                    <div class=\"limiter any-b0\">\r\n                                                    <h2>M\u00f6chten Sie spezifische Anforderungen an Luftf\u00fchrung, Validierung und Wartung diskutieren? <\/h2>\r\n                                                <p>Wir stehen Ihnen gerne zur Verf\u00fcgung.<\/p>\n                    <\/div>\r\n                                                    <ul class=\"contact-teaser-list list-reset\">\r\n                                                                                <li>\r\n                                <a href=\"https:\/\/skan.com\/de\/kontakt?pid=60071\" target=\"_self\">\r\n                                                                        \r\n                                                                            <span class=\"text\">Kontakt<\/span>\r\n                                    \r\n                                    <span aria-hidden=\"true\"><\/span>\r\n                                <\/a>\r\n                            <\/li>\r\n                                                                                <li>\r\n                                <a href=\"https:\/\/skan.com\/de\/expertise\/pharma\/isolatortechnologie?pid=60071\" target=\"_self\">\r\n                                                                        \r\n                                                                            <span class=\"text\">Mehr zu Isolatortechnologie<\/span>\r\n                                    \r\n                                    <span aria-hidden=\"true\"><\/span>\r\n                                <\/a>\r\n                            <\/li>\r\n                                            <\/ul>\r\n                            <\/div>\r\n        <\/div>\r\n    <\/section>\r\n","protected":false},"featured_media":0,"template":"","meta":{"_acf_changed":false,"inline_featured_image":false,"footnotes":""},"class_list":["post-60071","expertise","type-expertise","status-publish","hentry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Filter in aseptischen Prozessen | SKAN<\/title>\n<meta name=\"description\" content=\"Wie HEPA-Filter funktionieren, wie ihre Integrit\u00e4t per Scanning gepr\u00fcft wird und worauf es bei Integration und Wartung im Isolator ankommt.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/skan.com\/de\/expertise\/pharma\/filter\" \/>\n<meta property=\"og:locale\" content=\"de_DE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Filter in aseptischen Prozessen | SKAN\" \/>\n<meta property=\"og:description\" content=\"Wie HEPA-Filter funktionieren, wie ihre Integrit\u00e4t per Scanning gepr\u00fcft wird und worauf es bei Integration und Wartung im Isolator ankommt.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/skan.com\/de\/expertise\/pharma\/filter\" \/>\n<meta property=\"og:site_name\" content=\"SKAN\" \/>\n<meta property=\"article:modified_time\" content=\"2026-11-17T17:04:24+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/skan.com\\\/de\\\/expertise\\\/pharma\\\/filter\",\"url\":\"https:\\\/\\\/skan.com\\\/de\\\/expertise\\\/pharma\\\/filter\",\"name\":\"Filter in aseptischen Prozessen | SKAN\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/skan.com\\\/de\\\/#website\"},\"datePublished\":\"2026-11-16T14:57:02+00:00\",\"dateModified\":\"2026-11-17T17:04:24+00:00\",\"description\":\"Wie HEPA-Filter funktionieren, wie ihre Integrit\u00e4t per Scanning gepr\u00fcft wird und worauf es bei Integration und Wartung im Isolator ankommt.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/skan.com\\\/de\\\/expertise\\\/pharma\\\/filter#breadcrumb\"},\"inLanguage\":\"de\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/skan.com\\\/de\\\/expertise\\\/pharma\\\/filter\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/skan.com\\\/de\\\/expertise\\\/pharma\\\/filter#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Startseite\",\"item\":\"https:\\\/\\\/skan.com\\\/de\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Filter\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/skan.com\\\/de\\\/#website\",\"url\":\"https:\\\/\\\/skan.com\\\/de\\\/\",\"name\":\"SKAN\",\"description\":\"Ihr Partner f\u00fcr Forschungslaboratorien\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/skan.com\\\/de\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"de\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Filter in aseptischen Prozessen | SKAN","description":"Wie HEPA-Filter funktionieren, wie ihre Integrit\u00e4t per Scanning gepr\u00fcft wird und worauf es bei Integration und Wartung im Isolator ankommt.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/skan.com\/de\/expertise\/pharma\/filter","og_locale":"de_DE","og_type":"article","og_title":"Filter in aseptischen Prozessen | SKAN","og_description":"Wie HEPA-Filter funktionieren, wie ihre Integrit\u00e4t per Scanning gepr\u00fcft wird und worauf es bei Integration und Wartung im Isolator ankommt.","og_url":"https:\/\/skan.com\/de\/expertise\/pharma\/filter","og_site_name":"SKAN","article_modified_time":"2026-11-17T17:04:24+00:00","twitter_card":"summary_large_image","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/skan.com\/de\/expertise\/pharma\/filter","url":"https:\/\/skan.com\/de\/expertise\/pharma\/filter","name":"Filter in aseptischen Prozessen | SKAN","isPartOf":{"@id":"https:\/\/skan.com\/de\/#website"},"datePublished":"2026-11-16T14:57:02+00:00","dateModified":"2026-11-17T17:04:24+00:00","description":"Wie HEPA-Filter funktionieren, wie ihre Integrit\u00e4t per Scanning gepr\u00fcft wird und worauf es bei Integration und Wartung im Isolator ankommt.","breadcrumb":{"@id":"https:\/\/skan.com\/de\/expertise\/pharma\/filter#breadcrumb"},"inLanguage":"de","potentialAction":[{"@type":"ReadAction","target":["https:\/\/skan.com\/de\/expertise\/pharma\/filter"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/skan.com\/de\/expertise\/pharma\/filter#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Startseite","item":"https:\/\/skan.com\/de"},{"@type":"ListItem","position":2,"name":"Filter"}]},{"@type":"WebSite","@id":"https:\/\/skan.com\/de\/#website","url":"https:\/\/skan.com\/de\/","name":"SKAN","description":"Ihr Partner f\u00fcr Forschungslaboratorien","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/skan.com\/de\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"de"}]}},"permalink_manager":null,"_links":{"self":[{"href":"https:\/\/skan.com\/de\/wp-json\/wp\/v2\/expertise\/60071","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/skan.com\/de\/wp-json\/wp\/v2\/expertise"}],"about":[{"href":"https:\/\/skan.com\/de\/wp-json\/wp\/v2\/types\/expertise"}],"version-history":[{"count":39,"href":"https:\/\/skan.com\/de\/wp-json\/wp\/v2\/expertise\/60071\/revisions"}],"predecessor-version":[{"id":63242,"href":"https:\/\/skan.com\/de\/wp-json\/wp\/v2\/expertise\/60071\/revisions\/63242"}],"wp:attachment":[{"href":"https:\/\/skan.com\/de\/wp-json\/wp\/v2\/media?parent=60071"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}